Skip to content

Errata in ISO 10140

These are the 3 entries of the errata registry on ISO 10140-1:2021, in the order the registry lists them. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.

ISO 10140-1:2021, Annex H, Figure H.4 (a CI,r,50-2500 the reference floor cannot give)

Section titled “ISO 10140-1:2021, Annex H, Figure H.4 (a CI,r,50-2500 the reference floor cannot give)”
  • Location: Annex H, Figure H.4 “Example of form for expression of results” (printed p. 31), the rating line under the diagram. The form of ISO 10140-1:2010+A2:2014, Figure H.4 (printed p. 27), carries the same term.
  • The print: “Rating in accordance with ISO 717-2: = dB; = dB; = dB”. The 2010 form prints ” = dB; = dB” in the same line.
  • The problem: is the spectrum adaptation term of the reference floor with the covering (ISO 717-2:2020 A.2.2), taken from (Formula (1)). ISO 717-2:2020 Table 4 defines only from 100 Hz to 3 150 Hz, and the enlarged range of the NOTE to A.2.1 needs 50, 63 and 80 Hz as well, so no exists in those three bands and neither document defines . The form’s own table asks for from 50 Hz, the three bands where the reference values would be needed. H.5 i), which the form illustrates, asks for and or and , all of which Table 4 can give.
  • Evidence: the rating line of the form against ISO 717-2:2020 A.2.1, A.2.2 and Table 4, and against H.5 h) and i) of the same annex. Verified on PDF pages 35 and 37 (printed pp. 29 and 31) of ISO 10140-1:2021, on PDF pages 13, 17 and 18 (printed pp. 7, 11 and 12) of ISO 717-2:2020, and on PDF page 36 (printed p. 27) of BS EN ISO 10140-1:2010+A2:2014.
  • Library behaviour: building.laboratory_floor_covering_improvement reports the two ratings H.5 i) asks for and no ; the enlarged-range term of the measured bare floor, which is defined, comes from building.weighted_impact_rating_extended. The form itself is printed by LaboratoryFloorCoveringImprovementResult.report(), which puts those two ratings beside and and writes, where would go, that it is not formed because Table 4 starts at 100 Hz. No number the library reports depends on the form, and no change was required.
  • Status: unreported.

ISO 10140-1:2021, Annex J, Figure J.7 (“weighing curve” for “weighting curve”)

Section titled “ISO 10140-1:2021, Annex J, Figure J.7 (“weighing curve” for “weighting curve”)”
  • Location: Annex J, J.5.1, Figure J.7 “Sample form for expression of results” (PDF page 50, printed p. 44), the key beside the last two rows of the header of the form.
  • The print: ”… frequency range of weighing curve” above ”__________ test curve”.
  • The problem: “weighing” for “weighting”. The dotted line marks the frequency range of the reference curve that the ISO 717-1 rating shifts, the weighting curve; a weighing curve is a term of neither document. The form of BS EN ISO 10140-1:2010+A2:2014, Figure J.7, prints “frequency range of weighting curve” in the same place, so the letter was lost in the 2021 edition.
  • Evidence: Verified on PDF page 50 (printed p. 44) of ISO 10140-1:2021 against PDF page 49 (printed p. 40) of BS EN ISO 10140-1:2010+A2:2014.
  • Library behaviour: none to take; no number depends on it. The form that LaboratoryJointInsulationResult.report() prints labels the curve “shifted reference (ISO 717-1)” and draws it over the rating range only.
  • Status: unreported (typographic, no numerical consequence).

ISO 10140-1:2021, Annex J, Figure J.8 (the working range drawn as Δb and keyed as Δbn)

Section titled “ISO 10140-1:2021, Annex J, Figure J.8 (the working range drawn as Δb and keyed as Δbn)”
  • Location: Annex J, J.5.1, Figure J.8 (PDF page 52, printed p. 46), the dimension under the abscissa and the last line of the key. Figure J.8 of BS EN ISO 10140-1:2010+A2:2014 (PDF page 50, printed p. 41) prints the same pair.
  • The print: the arrow between and is labelled ""; the key reads ” working range, 3 mm”.
  • The problem: one quantity under two symbols, and the symbol the key explains is not the one drawn. The text that introduces the figure names it only in words, “indicating the working range of 3 mm” (J.5.1, PDF page 51, printed p. 45), so nothing else in the annex decides between the two.
  • Evidence: Verified on PDF page 52 (printed p. 46) of ISO 10140-1:2021, the drawing against its key, with the text of J.5.1 on PDF page 51 (printed p. 45); and on PDF page 50 (printed p. 41) of BS EN ISO 10140-1:2010+A2:2014.
  • Library behaviour: JointGapSeries.working_range_mm returns the two ends, , and its plot labels the shaded range “working range = 3 mm”, the symbol of the drawing. No number depends on the symbol, and no change was required.
  • Status: unreported (typographic, no numerical consequence).