Catalogue of plateau-method constants

Key references: Norton & Karczub 2003

The three numbers the plateau method needs to sketch a single panel’s transmission loss without solving the plate model: the mass one millimetre of the material brings, how high the plateau sits, and how wide it is in frequency. The first is a density in disguise, kilograms per square metre per millimetre, which is the density divided by a thousand; it is kept in that unit because that is the unit the method uses it in. The second is a transmission loss, the level the method draws as a horizontal line over the coincidence region, and it depends on the material and not on the thickness. These are the numbers the library’s own plateau-method prediction reads, and it takes a row of this table, or a row of your own, as its material. The measured insulation of real constructions is in the transmission loss catalogue.

Italic is a value this library worked out; a dotted underline is a cell that is not a plain number, and what it is reads on the cell; an asterisk is a note the page made about the row. Click a mark to read it, or give the table focus and press Enter to walk the marks with the arrow keys.

MaterialSurface density per mm kg/m² per mmCoincidence height dBPlateau frequency ratio B/ASource
Aluminium2.662911Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)
Brick2.1374.5Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)
Concrete2.28384.5Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)
Glass2.472710Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)
Lead11.2564Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)
Plaster1.71308Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)
Plywood0.57196.5Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)
Steel7.64011Norton & Karczub 2e Table 3.1, PDF page 261 (printed p. 241)