Skip to content

Errata in IEC 61063

This is the entry of the errata registry on IEC 61063:1991. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.

  • Location: clause 8.3, the where-list under Equation (2) and the NOTE that follows it.
  • The print: ” is the A-weighted sound pressure level in decibels at the measurement position”, with a capital , and in the NOTE “When the range of values of does not exceed 5 dB, a simple arithmetic average may be used.”
  • The problem: Equation (2) and the sentence that introduces it write , with the lower-case of the sum , and the where-list line itself speaks of the position; names no quantity of the standard.
  • Evidence: Equation (2), its where-list and the NOTE on PDF page 29 (printed p. 27) of IEC 61063:1991, the bilingual first edition of 1991-04, whose French text on PDF page 28 (printed p. 26) prints the same in the where-list and in the NOTE; and on PDF page 15 (printed p. 9) of BS EN 61063:1996, the English text of EN 61063:1996, which reproduces that same IEC 61063:1991, numbered IEC 1063:1991 there, without modification.
  • Library behaviour: turbine_sound_power averages the corrected position levels by Equation (2), and arithmetic_mean_allowed reads the NOTE on the range of the same levels (turbine_noise.py). No change was required.
  • Status: unreported.
Edit page

Published , updated