Errata in Jiménez et al. (2017)

These are the 2 entries of the errata registry on Jiménez et al. (2017), in the order the registry lists them. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.

Jiménez, Groby, Pagneux & Romero-García (2017), Appl. Sci. 7(6), 618, Eqs. (7)-(8)

Section titled “Jiménez, Groby, Pagneux & Romero-García (2017), Appl. Sci. 7(6), 618, Eqs. (7)-(8)”
  • Location: Eqs. (7) and (8), the rectangular-duct visco-thermal effective density and bulk modulus (Stinson’s series, used for the square necks and cavities of the slit + Helmholtz-resonator absorber).
  • The print: the leading normalising constant of both series is 4: and the matching factor inside .
  • The problem: the correct constant is 64 (a factor-16 error). Only 64 reproduces the exact limits of the model: as the boundary layers vanish and (the printed 4 gives ), and at DC the square duct’s tends to the exact Shah-London Poiseuille flow resistivity: the series value matches (in units of ), where is the double transverse-mode sum at ; the printed 4 gives sixteen times that.
  • Evidence: evaluation of both constants against the boundary-layer-free limits and the Shah-London exact square-duct value; the wide-duct limit of the series also only matches the papers’ own slit model (Eq. (6)) with 64.
  • Library behaviour: implements 64 with a docstring note; the limits are pinned in tests/materials/absorbers/test_slow_sound.py and the conformance check “Poiseuille limit (Stinson 1991)”.
  • Status: unreported (journal paper rather than a standard).

Jiménez et al. (2017), Appl. Sci. 7(6), 618 / Sci. Rep. 7, 5389, slit-radiation term

Section titled “Jiménez et al. (2017), Appl. Sci. 7(6), 618 / Sci. Rep. 7, 5389, slit-radiation term”
  • Location: Appl. Sci. Eq. (3), the characteristic radiation impedance of the slits, and the identical Methods reprint in the metadiffusers paper (Sci. Rep. 7, 5389, Eq. (5)).
  • The print: .
  • The problem: the term models the added radiation mass of the slit mouth, but the printed prefactor is an opposite-time-convention () expression inconsistent with the papers’ otherwise transfer-matrix chain (the off-diagonal slit matrices of Appl. Sci. Eq. (2) and the cotangent-type resonator impedance). Transcribed literally into that chain, the correction raises the slit-panel resonance where an added mass must lower it: for a 1 mm slit with a 30 mm lattice step and 50 mm period the absorption peak moves from 378.6 Hz to 386.8 Hz as printed, against 370.8 Hz with the mass sign. The neck end corrections of the same model behave correctly (they lower the resonator resonance).
  • Evidence: numerical evaluation of both signs of the correction against the uncorrected panel; the direction of the neck end corrections of the same papers as the consistent control.
  • Library behaviour: uses the added-mass sign ( in the convention of the library), conjugating the printed term exactly as it conjugates the papers’ Stinson duct series; direction and peak are pinned by test_slit_radiation_correction_lowers_resonance in tests/materials/absorbers/test_slow_sound.py.
  • Status: unreported (journal papers rather than standards).