Skip to content

Errata in ISO 8297

These are the 4 entries of the errata registry on ISO 8297:1994, in the order the registry lists them. The registry’s introduction says how each claim is checked against the printed page and what the status of an entry means.

ISO 8297:1994, 3.7 (a misspelt term in the heading of the definition)

Section titled “ISO 8297:1994, 3.7 (a misspelt term in the heading of the definition)”
  • Location: definition 3.7 (PDF page 11, printed p. 3) of BS ISO 8297:1994, the identical British adoption of ISO 8297:1994.
  • The print: “characteristics height of the plant, ”.
  • The problem: “characteristics” for “characteristic”. The symbol list of clause 4 on the same page (“Characteristic height of the plant, in metres”) and 9.2 c) (PDF page 13, printed p. 5: “the characteristic height of the plant, ”) write the term without the extra letter; the heading of the definition is the one place that names it otherwise.
  • Evidence: Verified on PDF page 11 (printed p. 3) of BS ISO 8297:1994, definition 3.7, against the symbol list of clause 4 on the same page and 9.2 c) on PDF page 13 (printed p. 5).
  • Library behaviour: none to take; no number depends on it. The height is plant_characteristic_height_m and the characteristic_height_m of the contour.
  • Status: unreported.

ISO 8297:1994, 9.1.1 b) (the aspect angle written with the symbol of the microphone’s 3 dB angle)

Section titled “ISO 8297:1994, 9.1.1 b) (the aspect angle written with the symbol of the microphone’s 3 dB angle)”
  • Location: clause 9.1.1 b) (PDF page 13, printed p. 5), against the symbol list of clause 4 (PDF page 11, printed p. 3), the aspect-angle callout of Figure 1 and clause 7.1 (PDF page 12, printed p. 4) of BS ISO 8297:1994, the identical British adoption of ISO 8297:1994.
  • The print: “from any point on the measurement contour, the plant area shall be seen inside an aspect angle, , not greater than 180° (see Figure 1)”.
  • The problem: clause 4 gives the two angles of the standard two symbols: is the “Angle at which the sensitivity of a directional microphone has fallen by 3 dB”, the angle 7.1 requires to exceed ±30° and 10.6 puts in dB, and is the “Aspect angle subtended at a microphone position by the extremities of the perimeter of the plant area”. Figure 1, to which 9.1.1 b) refers, labels the aspect angle . The clause therefore writes the aspect angle with the symbol of the microphone’s angle. Figure 1 also writes the bound as "", strict, where the clause says “not greater than 180°”.
  • Evidence: Verified on PDF page 13 (printed p. 5) of BS ISO 8297:1994, clause 9.1.1 b), against the symbol list on PDF page 11 (printed p. 3) and Figure 1 and clause 7.1 on PDF page 12 (printed p. 4).
  • Library behaviour: the aspect angle is of clause 4 and Figure 1, and the bound is the clause’s, at most 180° (check_plant_measurement, requirement aspect_angle, and PlantMeasurementContour.aspect_angles_deg); keeps its clause 4 meaning as directional_microphone_angle_deg. No change was required.
  • Status: unreported.

ISO 8297:1994, 10.4 (the area term written with a lower-case subscript)

Section titled “ISO 8297:1994, 10.4 (the area term written with a lower-case subscript)”
  • Location: clause 10.4, step 4 (PDF page 15, printed p. 7) of BS ISO 8297:1994.
  • The print: “Calculate an area term, , in decibels, for the measurement surface (as defined in ISO 3744)”.
  • The problem: the equation directly below the sentence writes dB with a capital subscript, and so do the symbol list of clause 4 (PDF page 11, printed p. 3: ” Area term, in decibels”) and the sum of 10.8 on the same page. The prose of 10.4 is the only place that writes the subscript in lower case; steps 5 to 7 name their terms with the symbols their equations use.
  • Evidence: Verified on PDF page 15 (printed p. 7) of BS ISO 8297:1994, clause 10.4, against its own equation and 10.8 on the same page and the symbol list on PDF page 11 (printed p. 3). The running text of this reprint is set apart from its equations, so the slip may belong to the British adoption rather than to ISO 8297:1994.
  • Library behaviour: none to take; the term is PlantSoundPowerResult.area_term_db, written in its docstring.
  • Status: unreported.

ISO 8297:1994, Table 3 (the 31.5 Hz octave printed as 31 Hz)

Section titled “ISO 8297:1994, Table 3 (the 31.5 Hz octave printed as 31 Hz)”
  • Location: Table 3, first row (PDF page 15, printed p. 7) of BS ISO 8297:1994.
  • The print: the first octave-band centre frequency of Table 3 is “31”.
  • The problem: 7.2 requires the centre frequencies of the bands to “correspond to those of ISO 266”, whose octave band is 31.5 Hz, and NOTE 8 (PDF page 14, printed p. 6) names the same band “31,5 Hz”. The row is the 31.5 Hz octave; its value, 0 dB/m, is unaffected.
  • Evidence: Verified on PDF page 15 (printed p. 7) of BS ISO 8297:1994, Table 3, against clause 7.2 on PDF page 13 (printed p. 5) and NOTE 8 on PDF page 14 (printed p. 6).
  • Library behaviour: PLANT_AIR_ABSORPTION_DB_PER_M keys the row as 31.5 Hz, the band the rest of the method names. No change of any value was required.
  • Status: unreported.
Edit page

Published , updated