How fast vibration dies away along a rail (EN 15461:2008+A1:2010).

A rail struck by a wheel carries the vibration away along itself as vertical and lateral bending waves, and the length of rail that radiates rolling noise is set by how fast those waves decay. The track decay rate is that attenuation in decibels per metre, one value per one-third octave band (3.6), and a vehicle type test by ISO 3095 needs a track whose decay rates are at least the lower limits of its Figure 3 (REFERENCE_TRACK_DECAY_LIMITS_DB_PER_M).

The measurement (clause 6). An accelerometer is fixed to the rail at the middle of a sleeper bay, and an instrumented hammer strikes the rail at a grid of positions measured in sleeper bays from it: every quarter bay out to bay 2 and a half, then every half bay to bay 4, every bay to bay 8, and then at bays 10, 12, 16, 20, 24, 30, 36, 42, 48, 54 and 66 (6.7 and Figure 2, TRACK_DECAY_EXCITATION_INDICES). The frequency response between force and response at each position, in mobility or accelerance, is reduced to its one-third octave band magnitude ; the one at the accelerometer itself is the direct response .

Clause 7 and Annex A, the rate. If the response decayed as , the decay rate would be dB/m, and the integral of the squared response along the rail would be (A.1). The standard estimates it from that integral rather than from a fitted slope,

(Formula 1, A.3), where is the length of rail each position stands for: from halfway to the position before it to halfway to the one after it, from 0 to halfway for the direct response and symmetrical about the last position (A.2) (track_decay_rate). The summation is dominated by the first 10 dB of decay, which is what radiates.

Formula 2, the floor. A grid that stops at cannot measure a rate below ; a band whose rate is less than twice that is unsuitable, and its value only an upper bound on the true one (clause 7). The response at the far end of the grid also has to be at least 10 dB below the direct one in every band (6.7).

Read from BS EN 15461:2008+A1:2010, which is identical to EN 15461:2008+A1:2010 (its national foreword).

Auto-generated from the source docstrings by scripts/generate_api_docs.py (make api-docs). Do not edit by hand.

Constant (tuple).

TRACK_DECAY_DIRECTIONS = ('vertical', 'lateral')

Constant (tuple).

TRACK_DECAY_EXCITATION_INDICES = (0.0, 0.25, 0.5, 0.75, 1.0, 1.25, 1.5, 1.75, 2.0, 2.25, 2.5, 3.0, 3.5, 4.0, 5.0, 6.0, 7.0, 8.0, 10.0, 12.0, 16.0, 20.0, 24.0, 30.0, 36.0, 42.0, 48.0, 54.0, 66.0)
track_decay_excitation_positions(
*,
sleeper_spacing_m: float = 0.6,
) -> NDArray[np.float64]

The hammer positions of Figure 2, in metres from the accelerometer.

Parameters

NameDescription
sleeper_spacing_mThe distance between sleepers, in metres; the 0,6 m 6.7 prescribes for a rail without periodic supports by default.

Returns: The 29 distances of TRACK_DECAY_EXCITATION_INDICES times the sleeper spacing, read-only.

Raises

ExceptionWhen
ValueErrorFor a spacing that is not positive.
track_decay_rate(
responses: ArrayLike,
*,
frequencies_hz: ArrayLike,
distances_m: ArrayLike | None = None,
sleeper_spacing_m: float = 0.6,
direction: str = 'vertical',
) -> TrackDecayRate

The decay rate of a rail from its responses along it (clause 7, Formula 1).

in each band, with the length of rail each position stands for (A.2). Mobility and accelerance give the same rates, since only the ratio to the direct response enters.

Parameters

NameDescription
responsesThe one-third octave band magnitudes , one row per excitation position, nearest first, the direct response in the first row, and one column per band. Magnitudes, not levels: a level in decibels is 10 ** (level / 20).
frequencies_hzThe nominal frequency of each band, in hertz; 6.6 asks for at least 100 Hz to 5 000 Hz.
distances_mThe excitation positions, in metres from the accelerometer, starting at 0 and increasing. When omitted, the 29 positions of Figure 2 at sleeper_spacing_m.
sleeper_spacing_mThe sleeper spacing the Figure 2 grid is laid out in, in metres, when distances_m is omitted.
direction"vertical" or "lateral".

Returns: The rates, with the grid and the responses they came from.

Raises

ExceptionWhen
ValueErrorFor responses that are not positive and finite, a grid that is not finite, has fewer than two positions, does not start at 0 or does not strictly increase, frequencies that do not name distinct bands in increasing order, or shapes that do not agree.
TrackDecayRate(
direction: str,
frequencies_hz: NDArray[np.float64],
decay_rates_db_per_m: NDArray[np.float64],
distances_m: NDArray[np.float64] | None = None,
responses: NDArray[np.float64] | None = None,
)

The decay rates of a rail in one direction, by one-third octave band (EN 15461).

Built by track_decay_rate from a set of frequency responses, or directly from the rates of a report, which is all the ISO 3095 check needs.

Parameters

NameDescription
direction"vertical" or "lateral".
frequencies_hzThe nominal band frequencies, in hertz.
decay_rates_db_per_mThe decay rate of each band, in dB/m.
distances_mThe excitation positions, in metres from the accelerometer: the direct one at 0 m first, then strictly increasing, at least two in all; None for rates taken from a report.
responsesThe magnitude of each response, one row per position and one column per band, positive and finite, in whatever unit the mobility or accelerance was measured in; None for rates taken from a report.

property

How far the response at the farthest position is below the direct one, per band, in dB (6.7).

property

Whether the farthest response is at least 10 dB below the direct one in every band (6.7).

TrackDecayRate.minimum_measurable_db_per_m

Section titled “TrackDecayRate.minimum_measurable_db_per_m”

property

The floor of Formula 2, in dB/m; None without the grid.

TrackDecayRate.plot(
ax: Axes | None = None,
*,
limit_db_per_m: Mapping[float, float] | None = None,
language: str = 'en',
**kwargs: Any,
) -> Axes

Draw the rates as EN 15461 9.2 presents them.

Decay rate on a logarithmic axis from 0,01 dB/m to 100 dB/m against equidistant one-third octave bands, with the bands clause 7 finds unsuitable marked and a lower limit drawn when one is given.

Parameters

NameDescription
axAxes to draw on; a new figure is made when omitted.
limit_db_per_mA lower limit, nominal frequency to rate, such as one direction of REFERENCE_TRACK_DECAY_LIMITS_DB_PER_M.
language"en" or "es".
kwargsPassed to the rate line.

Returns: The axes drawn on.

TrackDecayRate.rate_at(frequency_hz: float) -> float

The decay rate of the band a nominal frequency names, in dB/m.

Parameters

NameDescription
frequency_hzA nominal band frequency, in hertz.

Returns: The rate of that band.

Raises

ExceptionWhen
KeyErrorIf the spectrum has no such band.

property

Per band, whether the floor of Formula 2 is at most half the rate (clause 7).

A band that is not is an upper bound on the true rate. Every band is taken as suitable when the grid is not known.