<!-- canonical: https://docs.jmrp.io/phonometry/vibration/structural/ -->
Source: https://docs.jmrp.io/phonometry/vibration/structural/

# Structure-borne sources

A machine fixed to a building radiates sound twice: directly from its own
vibrating surface, and indirectly by injecting **structure-borne power** into
the structure, which carries it away and re-radiates it in distant rooms. Nine
pages cover both paths and the question that is not about sound at all, six of
them here and three elsewhere on the site: one estimates the direct radiation
from the surface vibration itself, six characterise the second, sneakier
structure-borne path end to end, from describing and measuring the vibration
and characterising the isolators to quantifying the power and predicting the
level a listener finally hears, and the last two ask instead whether the
shaking damages the building, and at what frequency the building answers.

The language comes first.
[Mechanical mobility and the FRF family (ISO 7626-1)](https://docs.jmrp.io/phonometry/vibration/mechanical-mobility/)
defines the motion-per-force frequency-response functions (receptance,
mobility, accelerance and their reciprocals) that every later standard speaks,
with the closed-form SDOF resonator as the reference and the ISO 7626-2
measurement acceptance criteria. Source and receiver *mobilities* are what
decide how much power actually couples across an interface, which is why this
vocabulary matters.
[Mobility by impact excitation (ISO 7626-5)](https://docs.jmrp.io/phonometry/vibration/impact-mobility/)
measures the same functions with an instrumented hammer instead of an attached
exciter: the force and exponential windows an impact record needs, the average
over impacts with its coherence, the damping an exponential window adds taken
away again by Annex A, and the checks that decide whether a record may be used
at all.

Three pages then characterise the path elements.
[Bending-wave transmission at plate junctions (Cremer/Craik/Hopkins)](https://docs.jmrp.io/phonometry/vibration/junction-transmission/)
follows the power across the structure itself, with the wave-approach
transmission coefficients for rigid X, T, L and in-line junctions, their
diffuse-field angular average, and the coupling loss factor and vibration
reduction index Kij they yield, and, for joints no wave model describes,
the experimental route that inverts the same coupling loss factors from
measured subsystem energies.
[Transfer stiffness of resilient elements (ISO 10846)](https://docs.jmrp.io/phonometry/vibration/transfer-stiffness/)
measures the dynamic transfer stiffness of the isolators, mounts and hoses
inserted precisely to break the transmission path, by the direct and indirect
(transmissibility) methods, and their low-frequency stiffness by the
driving-point method, one value per one-third-octave band.
[Sound power from surface vibration (ISO/TS 7849)](https://docs.jmrp.io/phonometry/devices/emission/vibration-sound-power/)
handles the direct radiation: the airborne power estimated from surface
velocity and a radiation factor, without any acoustic measurement.

The last two pages close the chain on the source and the receiver.
[Structure-borne sound power of equipment (EN 15657)](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/)
measures what a machine injects, via the reception-plate method, and derives
the plate-independent source quantities (blocked force, characteristic power
level, free velocity).
[Installed structure-borne sound (EN 12354-5)](https://docs.jmrp.io/phonometry/buildings/design/installed-structure-borne/)
consumes exactly those quantities, couples them through source and receiver
mobilities, and predicts the sound pressure level in the receiving room,
which is where this section meets the
[sound insulation](https://docs.jmrp.io/phonometry/buildings/insulation/) models.

One page here asks a different question of the same shaking.
[Vibration damage to structures (DIN 4150-3)](https://docs.jmrp.io/phonometry/vibration/structural-damage/)
is not about what a building radiates but about whether it cracks, and it
answers with a screening comparison rather than a verdict: the guideline values
for the peak particle velocity, chosen by building class and by how often the
vibration occurs at a foundation and in the topmost floor plane, and by pipe
material on a buried pipeline. Keeping under one is where experience says the
question stops; exceeding one sends the reader to the stress calculation, not
to a finding of damage.
[Predicting a building's own frequency (ISO 4866)](https://docs.jmrp.io/phonometry/vibration/building-response/)
is what those guideline values are read at when nobody could measure it: the
empirical predictors of Annex D, the error each one admits, and the damping
range the annex reports without offering a way to predict it.

## Pages in this section

- [Mechanical mobility and the FRF family (ISO 7626-1)](https://docs.jmrp.io/phonometry/vibration/mechanical-mobility/):
  the FRF family, conversions and the SDOF reference resonator.
- [Mobility by impact excitation (ISO 7626-5)](https://docs.jmrp.io/phonometry/vibration/impact-mobility/):
  the force and exponential windows, the average over impacts with its
  coherence, the Annex A damping correction and the checks on the record.
- [Bending-wave transmission at plate junctions (Cremer/Craik/Hopkins)](https://docs.jmrp.io/phonometry/vibration/junction-transmission/):
  the wave-approach transmission coefficients for rigid X, T, L and in-line
  junctions, their angular average and the derived coupling loss factor and Kij,
  plus experimental SEA: coupling loss factors inverted from measured energies
  by power injection, with the modal densities they need.
- [Transfer stiffness of resilient elements (ISO 10846)](https://docs.jmrp.io/phonometry/vibration/transfer-stiffness/):
  dynamic transfer stiffness of isolators by the direct, indirect and
  driving-point methods, in one-third-octave bands, with the checks of the rig.
- [Vibration damage to structures (DIN 4150-3)](https://docs.jmrp.io/phonometry/vibration/structural-damage/):
  the guideline peak velocities of Tables 1, 2 and 3, the reading of Bild 1
  between them, and the bending stress a measured velocity implies.
- [Predicting a building's own frequency (ISO 4866)](https://docs.jmrp.io/phonometry/vibration/building-response/):
  the four empirical predictors of Annex D, the ± 50 % they admit, and the
  measured damping range.

## See also

Pages elsewhere on the site that this section leans on:

- [Sound power from surface vibration (ISO/TS 7849)](https://docs.jmrp.io/phonometry/devices/emission/vibration-sound-power/):
  radiated airborne power from surface velocity and a radiation factor.
- [Structure-borne sound power of equipment (EN 15657)](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/):
  the reception-plate method and plate-independent source quantities.
- [Installed structure-borne sound (EN 12354-5)](https://docs.jmrp.io/phonometry/buildings/design/installed-structure-borne/):
  the predicted receiving-room level from installed equipment.

## What this section does not cover

The junction coefficients are a **closed-form idealisation** for a rigid,
simply supported junction between homogeneous plates, not a measurement: the
empirical vibration reduction index obtained from a direction-averaged
velocity level difference is ISO 10848, in [Laboratory flanking
transmission](https://docs.jmrp.io/phonometry/buildings/insulation/flanking-lab/). The
straight-section coefficient is undefined for the T and L geometries, which
have no collinear third plate, so only the corner path applies there.

The FRF page implements ISO 7626-1 and the ISO 7626-2 acceptance criteria for
an attached exciter, and the impact page ISO 7626-5; the conversions return
element-wise *free* reciprocals, correct for a driving-point or single-path
use, not for a full FRF matrix, whose blocked matrix quantities are not built.
The impact page estimates the damping one mode at a time, so closely spaced
modes need a multi-mode curve fitter, which is not provided.

On the isolator page, one of the standard's own validity checks is described
rather than computed: the linearity test (two input spectra 10 dB apart
must give transfer-stiffness levels within 1.5 dB, clause 7.7 of ISO 10846-2, -4 and -5 and clause 7.6 of
ISO 10846-3). Finally, nothing here
designs an isolator or a floating base: the pages characterise elements and
predict transmission, and the sizing decision stays yours.