# Errata in ISO 9295

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-9295/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-9295/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 9295: 2 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 2 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on UNE-EN ISO 9295:2015, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## UNE-EN ISO 9295:2015, Tables 1 and 2 (forty-three cells where a 0 of Annex A is printed as another digit)

- **Location:** Tables 1 and 2, "Valores del coeficiente de absorción por el
  aire", on printed folios 15 and 16 of UNE-EN ISO 9295:2015 (October 2015),
  which declares itself the Spanish version of EN ISO 9295:2015 and adopts ISO
  9295:2015 without modification. The two tables give the air absorption
  coefficient $\alpha$ in Np/m at a static pressure of 101.325 kPa, for 26
  frequencies from 10 000 Hz to 22 400 Hz, at 18, 20, 21, 22, 23, 24, 25 and
  27 °C and at 40 %, 50 % and 60 % relative humidity: 624 cells. Clause 7.2
  reads $\alpha$ from them into the room constant of Formula (7), and the
  normative Annex A gives the formulae they are computed from.
- **The print:** every cell carries four decimals, with the decimal comma and
  the last digit set apart, "0,027 7".
- **The problem:** forty-three cells contradict Annex A, and all forty-three
  in the same way: the value Annex A gives ends in 0, and a 0 is printed as
  another digit. In forty of them it is the fourth decimal, printed as the
  third repeated ("0,027 7" where Annex A gives 0.027 0). The other three are
  cells whose Annex A value ends in two zeros (two more such cells, both
  0.020 0 in Table 1, at 10 500 Hz, 20 °C and 50 % and at 11 000 Hz, 18 °C
  and 60 %, are printed correctly), and there it is the third decimal that
  takes the digit before it: "0,033 0" where Annex A gives
  0.030 0, and "0,04 4" and "0,05 50", with their digit groups set out of place
  as well, where Annex A gives 0.040 0 and 0.050 0. The defect is confined to
  zeros and is not a matter of rounding: the other 581 cells are Annex A to
  the last digit (see the evidence below), and of the 60 cells whose Annex A
  value ends in 0, these 43 are misprinted while 17 are printed with their 0.
  The errors run from one unit of the fourth decimal, where the repeated digit
  is a 1 ("0,051 1" for 0.051 0), to 0.005 0 Np/m, where "0,05 50" stands for
  0.050 0 at 21 500 Hz, 27 °C and 60 %. The three cells whose Annex A value
  ends in two zeros are each printed exactly 10 % high; read into Formula (7),
  any of them makes the air absorption area 10 % too large, and the room
  constant, and with it the sound power level of Formula (6), at least 0.41 dB
  too high. The cells, by table and frequency:
  - **Table 1, 13 500 Hz** (PDF page 15, printed folio 15): 20 °C and 60 %, "0,027 7" for 0.027 0; 21 °C and 40 %, "0,036 6" for 0.036 0; 21 °C and 60 %, "0,026 6" for 0.026 0; 22 °C and 40 %, "0,035 5" for 0.035 0.
  - **Table 1, 15 500 Hz** (PDF page 15, printed folio 15): 22 °C and 40 %, "0,044 4" for 0.044 0.
  - **Table 1, 16 500 Hz** (PDF page 15, printed folio 15): 21 °C and 50 %, "0,043 3" for 0.043 0.
  - **Table 1, 18 000 Hz** (PDF page 15, printed folio 15): 20 °C and 60 %, "0,045 5" for 0.045 0.
  - **Table 1, 19 000 Hz** (PDF page 15, printed folio 15): 21 °C and 60 %, "0,048 8" for 0.048 0.
  - **Table 1, 20 000 Hz** (PDF page 15, printed folio 15): 22 °C and 60 %, "0,051 1" for 0.051 0.
  - **Table 2, 10 000 Hz** (PDF page 16, printed folio 16): 27 °C and 50 %, "0,014 4" for 0.014 0.
  - **Table 2, 11 000 Hz** (PDF page 16, printed folio 16): 25 °C and 50 %, "0,018 8" for 0.018 0.
  - **Table 2, 11 500 Hz** (PDF page 16, printed folio 16): 23 °C and 50 %, "0,021 1" for 0.021 0.
  - **Table 2, 13 000 Hz** (PDF page 16, printed folio 16): 25 °C and 60 %, "0,021 1" for 0.021 0.
  - **Table 2, 13 500 Hz** (PDF page 16, printed folio 16): 27 °C and 60 %, "0,021 1" for 0.021 0.
  - **Table 2, 14 000 Hz** (PDF page 16, printed folio 16): 24 °C and 40 %, "0,035 5" for 0.035 0; 24 °C and 60 %, "0,025 5" for 0.025 0.
  - **Table 2, 14 500 Hz** (PDF page 16, printed folio 16): 24 °C and 50 %, "0,031 1" for 0.031 0; 25 °C and 40 %, "0,036 6" for 0.036 0; 25 °C and 50 %, "0,033 0" for 0.030 0; 27 °C and 50 %, "0,028 8" for 0.028 0; 27 °C and 60 %, "0,024 4" for 0.024 0.
  - **Table 2, 15 000 Hz** (PDF page 16, printed folio 16): 24 °C and 50 %, "0,033 3" for 0.033 0.
  - **Table 2, 15 500 Hz** (PDF page 16, printed folio 16): 24 °C and 50 %, "0,035 5" for 0.035 0; 27 °C and 40 %, "0,038 8" for 0.038 0.
  - **Table 2, 16 000 Hz** (PDF page 16, printed folio 16): 24 °C and 40 %, "0,044 4" for 0.044 0; 24 °C and 60 %, "0,032 2" for 0.032 0.
  - **Table 2, 16 500 Hz** (PDF page 16, printed folio 16): 23 °C and 60 %, "0,035 5" for 0.035 0.
  - **Table 2, 17 000 Hz** (PDF page 16, printed folio 16): 25 °C and 50 %, "0,04 4" for 0.040 0.
  - **Table 2, 18 000 Hz** (PDF page 16, printed folio 16): 23 °C and 60 %, "0,041 1" for 0.041 0; 27 °C and 60 %, "0,036 6" for 0.036 0.
  - **Table 2, 18 500 Hz** (PDF page 16, printed folio 16): 24 °C and 40 %, "0,056 6" for 0.056 0; 24 °C and 50 %, "0,048 8" for 0.048 0.
  - **Table 2, 19 500 Hz** (PDF page 16, printed folio 16): 23 °C and 50 %, "0,054 4" for 0.054 0.
  - **Table 2, 20 000 Hz** (PDF page 16, printed folio 16): 24 °C and 60 %, "0,048 8" for 0.048 0.
  - **Table 2, 20 500 Hz** (PDF page 16, printed folio 16): 23 °C and 40 %, "0,067 7" for 0.067 0; 24 °C and 40 %, "0,066 6" for 0.066 0.
  - **Table 2, 21 000 Hz** (PDF page 16, printed folio 16): 23 °C and 60 %, "0,054 4" for 0.054 0.
  - **Table 2, 21 500 Hz** (PDF page 16, printed folio 16): 23 °C and 40 %, "0,072 2" for 0.072 0; 24 °C and 40 %, "0,071 1" for 0.071 0; 27 °C and 60 %, "0,05 50" for 0.050 0.
  - **Table 2, 22 000 Hz** (PDF page 16, printed folio 16): 24 °C and 60 %, "0,057 7" for 0.057 0; 25 °C and 50 %, "0,063 3" for 0.063 0.
  - **Table 2, 22 400 Hz** (PDF page 16, printed folio 16): 25 °C and 50 %, "0,065 5" for 0.065 0.
- **Evidence:** Verified on PDF pages 15 and 16 (printed pp. 15 and 16) of
  UNE-EN ISO 9295:2015, where each of the forty-three cells was read on the
  page before being listed. Annex A, on PDF pages 25 and 26 (printed pp. 25
  and 26) of the same edition, was evaluated for all 624 cells: the 581 not
  listed reproduce to the fourth decimal when the temperature is converted as
  $\theta + 273.16$ K, and of the conversions from $\theta + 273.15$ K to
  $\theta + 273.18$ K in steps of 0.002 K that is the only one that
  reproduces all of them, so the tables were computed with the 273.16 K of
  the triple point where the Celsius scale puts 273.15 K. That offset is a
  property of the tables rather than a misprint, and a small one: at
  $\theta + 273.15$ K, 61 of the 581 move by one unit of the fourth
  decimal and none by more than 0.000 063 Np/m.
  For one listed cell the two conversions round apart, 19 500 Hz at 23 °C and
  50 %, which is 0.054 0 at 273.16 K and 0.054 1 at 273.15 K against the
  0.054 4 printed; the entry gives the table's own conversion throughout. The
  2013 draft, BS EN ISO 9295 (DPC 13/30264708), prints the same 624 cells on
  PDF pages 15 and 16 (printed pp. 7 and 8) of ISO/DIS 9295, so the defect
  came through from the draft to the standard.
- **Library behaviour:** does not read the tables. `air_absorption_np_per_m`
  in
  [`sound_power_high_frequency`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/sound_power_high_frequency.py)
  evaluates Annex A with the library's ISO 9613-1 implementation and
  $T = \theta + 273.15$ K, and `room_constant_from_air_absorption` feeds
  it to Formula (7). The 624 cells are transcribed in
  [`tests/reference_data/emission.py`](https://github.com/jmrplens/phonometry/blob/main/tests/reference_data/emission.py)
  with the forty-three named in `ISO9295_MISPRINTED_CELLS`;
  [`tests/emission/test_sound_power_high_frequency.py`](https://github.com/jmrplens/phonometry/blob/main/tests/emission/test_sound_power_high_frequency.py)
  and the conformance checks "ISO 9295:2015 Table 1" and "ISO 9295:2015 Table
  2" pin the 581 to the digit and hold each of the forty-three to what the page
  prints: Annex A with its first trailing 0 set as the digit before it.
- **Status:** unreported.

## UNE-EN ISO 9295:2015, Formula (A.5) (the oxygen relaxation frequency set with a digit zero)

- **Location:** Annex A (normative), "Cálculo del coeficiente de absorción
  por el aire", Formula (A.5) on printed folio 26 of UNE-EN ISO 9295:2015
  (October 2015), the Spanish version of EN ISO 9295:2015, which adopts ISO
  9295:2015 without modification.
- **The print:** the symbol list on printed folio 25 defines
  $f_{\mathrm{r,O}}$, "frecuencia de relajación del oxígeno", with the letter
  O, and Formula (A.3) at the top of folio 26 computes it under that name.
  Formula (A.5), which evaluates $\alpha$ from it, sets the same frequency as
  $f_{\mathrm{r,0}}$, with the digit zero, in both places it appears: the
  denominator $f_{\mathrm{r,0}} + f^2/f_{\mathrm{r,0}}$ of the oxygen term.
- **The problem:** the glyph in (A.5) is the narrow digit of $p_{\mathrm{s0}}$
  on the same page, not the round letter of (A.3), and the PDF's own text
  layer agrees, "f r,O" in the symbol list and in (A.3) and "f r,0" twice in
  (A.5). A reader who takes the subscript at its word looks for a quantity
  $f_{\mathrm{r,0}}$ that the annex never defines. The formula is right once
  the symbol is read as the oxygen relaxation frequency, which is the only
  frequency (A.3) gives, so no value of $\alpha$ changes.
- **Evidence:** Verified on PDF pages 25 and 26 (printed pp. 25 and 26) of
  UNE-EN ISO 9295:2015, on the page image and in the text layer. The 2013
  draft, BS EN ISO 9295 (DPC 13/30264708), defines $f_{\mathrm{r,O}}$ on PDF
  page 24 (printed p. 16) and sets $f_{\mathrm{r,0}}$ in (A.5) on PDF page 25
  (printed p. 17), so the slip came through from the draft to the standard.
- **Library behaviour:** unaffected. `air_absorption_np_per_m` in
  [`sound_power_high_frequency`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/emission/sound_power_high_frequency.py)
  evaluates Annex A through the library's ISO 9613-1 implementation, which
  names the oxygen relaxation frequency `fro`, and the 581 correctly printed
  cells of Tables 1 and 2 confirm the reading.
- **Status:** unreported.
