# Errata in ISO 6926

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-6926/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-6926/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-10-28T03:12:25Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 6926: 1 defect in the printed text, with the evidence and what phonometry does about it.

---

This is the entry of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 6926:2016. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 6926:2016, Annex A, Formula (A.1) (d_0 as half of a length ISO 3745 already halves)

- **Location:** Annex A (informative), A.2 a), Formula (A.1) and the
  definition of $d_0$ beneath it (PDF page 22, printed p. 16) of
  ISO 6926:2016, third edition, read against ISO 3745:2012, 3.14 (PDF page 13,
  printed p. 4). The Spanish adoption UNE-EN ISO 6926:2016 prints the same
  definition.
- **The print:** $f_\mathrm{k} = \dfrac{c}{2\pi} \cdot \dfrac{1}{d_0}$, with
  "$d_0$ is half the characteristic source dimension of the source (see
  ISO 3745), in metres", and the NOTE "the knee frequency is defined as the
  frequency at which the radiation efficiency has dropped 3 dB relative its
  maximum value at high frequencies". ISO 3745:2012 3.14 defines the
  characteristic source dimension, with the same symbol $d_0$, as the
  "distance from the origin of the co-ordinate system to the farthest corner
  of the reference box".
- **The problem:** the length ISO 3745 calls $d_0$ is already a radius, the
  distance from the centre of the source to its farthest corner, so half of
  it is a quarter of the source's size. The NOTE places the knee where the
  radiation efficiency of a pulsating sphere, $(ka)^2/(1 + (ka)^2)$, has
  fallen to half, at $ka = 1$, which is Formula (A.1) with $d_0$ the radius
  $a$. Halving the ISO 3745 length again doubles $f_\mathrm{k}$ and moves the
  switch between Formulae (A.2) and (A.3) an octave up. The definition gives
  the symbol two meanings in two standards that cite each other.
- **Evidence:** Verified on PDF page 22 (printed p. 16) of ISO 6926:2016 and
  on PDF page 13 (printed p. 4) of BS EN ISO 3745:2012; the physical reading
  rests on the radiation efficiency of a pulsating sphere, a recomputation
  rather than a printed value.
- **Library behaviour:** `knee_frequency` takes the $d_0$ that enters
  Formula (A.1), a radius-like length, and its docstring points here; which
  length that is stays with the caller. No number the library reports depends
  on the choice. No change was required.
- **Status:** unreported.