# Errata in ISO 3095

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-3095/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-3095/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 3095: 3 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 3 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 3095:2013, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 3095:2013, Table G.1 (the standard uncertainty of the 25 m microphone distance printed as 0.004 dB)

- **Location:** Annex G (informative), Table G.1, the $\delta_\mathrm{distance}$
  row, printed p. 49.
- **The print:** "for a microphone distance of 25 m: ±0,07 dB" in the
  Uncertainty interval column and "for a microphone distance of 25 m:
  0,004 dB" in the Standard uncertainty column; the 7,5 m line of the same row
  prints ±0,23 dB and 0,13 dB.
- **The problem:** G.3 derives every standard uncertainty of the table from
  its interval as $u(x_i) = a/\sqrt{3}$ (Formula G.2), and so does every other
  row: ±0.25 dB gives 0.14 dB, ±0.44 dB gives 0.25 dB, and the 7.5 m line of
  this row gives $0.23/\sqrt{3} = 0.13$ dB, as printed. For ±0.07 dB the
  formula gives $0.07/\sqrt{3} = 0.040$ dB. The printed 0.004 dB is ten
  times smaller, a digit zero too many after the decimal comma; the cell
  should read 0.04 dB.
- **Evidence:** Table G.1 read on PDF page 55 (printed p. 49) and Formula G.2
  on PDF page 54 (printed p. 48) of ISO 3095:2013 (third edition,
  2013-08-01).
- **Library behaviour:** Table G.1 is not published by the library;
  [`pass_by_uncertainty`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/environment/sources/rolling_stock_noise.py)
  takes each input as a value and its standard uncertainty, and
  `metrology.rectangular(0.0, 0.07)` gives the 0.040 dB of Formula G.2. The
  conformance check "ISO 3095:2013 Table G.1" holds the eighteen rectangular
  rows whose print Formula G.2 reproduces and leaves this cell out. No change
  was required.
- **Status:** unreported.

## ISO 3095:2013, Table G.1 against Table G.2 (the ground-level uncertainty at 7.5 m printed as 0.55 dB in one and 0.30 dB in the other)

- **Location:** Annex G (informative), the $\delta_\mathrm{ground\ level,7.5}$
  row of Table G.1, printed p. 49, and the $\delta_\mathrm{ground\ level}$ row
  of Table G.2, printed p. 51.
- **The print:** Table G.1 gives the interval "[0 dB; 1,03 dB]" and the
  standard uncertainty "0,55 dB" with "$\Delta L_p$ = 0,515 dB" for a
  microphone at 7,5 m. Table G.2, the example of G.6 for a standstill
  measurement whose ground "over a distance of 7,5 m varies between 0 and 2 m
  below to the top of the rail", uses the same correction 0,515 dB with a
  standard uncertainty of 0,30 dB.
- **The problem:** footnote a of Table G.1 treats an unsymmetrical range
  $[a; b]$ as a symmetric one about its mean, which is where the correction
  $(0 + 1.03)/2 = 0.515$ dB comes from, and Formula G.2 then gives the half
  width over $\sqrt{3}$: $0.515/\sqrt{3} = 0.297$ dB, the 0.30 dB of Table
  G.2. The 25 m line of the same quantity follows that arithmetic,
  $0.165/\sqrt{3} = 0.10$ dB as printed. The 0.55 dB of Table G.1 is
  neither the half width nor the whole width over $\sqrt{3}$ (0.59 dB); the
  cell should read 0.30 dB. The two tables also differ on the distance at
  7.5 m, where Table G.1 prints 0.13 dB and Table G.2 carries 0.06 dB without
  saying where that value comes from; the combined 0.83 dB of Table G.2 needs
  its 0.06 dB (0.13 dB would give 0.84 dB), so that difference is recorded
  here and not corrected.
- **Evidence:** Table G.1 read on PDF page 55 (printed p. 49), Formula G.2 and
  footnote a on PDF page 54 (printed p. 48), and Table G.2 on PDF pages 56 and
  57 (printed pp. 50 and 51) of ISO 3095:2013 (third edition, 2013-08-01).
- **Library behaviour:** the conformance checks "ISO 3095:2013 Table G.2" feed
  [`pass_by_uncertainty`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/environment/sources/rolling_stock_noise.py)
  the thirteen rows of Table G.2 as printed, 0.30 dB and 0.06 dB included, and
  reproduce its 55.68 dB, 0.83 dB and 1.66 dB. No change was required.
- **Status:** unreported.

## ISO 3095:2013, Table G.1 (the wind screen interval printed with its bounds out of order)

- **Location:** Annex G (informative), Table G.1, the
  $\delta_\mathrm{slm,\ wind\ screen}$ row, printed p. 49.
- **The print:** "Damping of the wind screen", interval "[0,12 dB; 0 dB]",
  standard uncertainty "0,03 dB" and "$\Delta L_p$ = 0,06 dB".
- **The problem:** footnote a writes an unsymmetrical range as $[a; b]$, and
  the four other rows that use one write the lower bound first: "[−0,21 dB;
  0 dB]" for the distortion factor of the calibrator, "[−1,5 dB; 1 dB]" for
  impulses, and "[0 dB; 1,03 dB]" and "[0 dB; 0,33 dB]" for the ground level
  at 7.5 m and at 25 m. Printed as it is, the wind screen interval has its
  lower bound above its upper one, and is empty. It should read either
  [−0.12 dB; 0 dB], a range that lowers the reading written the way the
  distortion row writes its own, whose mean value correction footnote a says
  "increases the average sound level", or [0 dB; 0.12 dB], written the way
  the ground-level rows write theirs. Both readings give the printed 0.03 dB
  and 0.06 dB, so the table does not say which one was meant.
- **Evidence:** Table G.1 and its footnote a read on PDF page 55 (printed
  p. 49) and on PDF page 54 (printed p. 48) of ISO 3095:2013 (third edition,
  2013-08-01).
- **Library behaviour:** the library reads no interval of Table G.1; the
  conformance check "ISO 3095:2013 Table G.1" uses the half width 0.06 dB and
  the Table G.2 checks the correction and uncertainty as printed. No change
  was required.
- **Status:** unreported.