# Errata in ISO 16283

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-16283/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-16283/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:13Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 16283: 4 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 4 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 16283-1:2014 and ISO 16283-2:2020, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 16283-1:2014, Clause 6 (a source-room reverberation time)

- **Location:** Clause 6 "General", the paragraph on the reverberation time
  (printed p. 6).
- **The print:** "For the reverberation time, the low-frequency procedure
  shall be used for the 50 Hz, 63 Hz, and 80 Hz one-third octave bands in
  **the source and/or receiving room** when its volume is smaller than $25\ \text{m}^3$
  (calculated to the nearest cubic metre)."
- **The problem:** ISO 16283-1 measures no source-room reverberation time, so
  there is nothing in the source room for a reverberation-time procedure to be
  used on. The first paragraph of the same clause, five paragraphs and a
  NOTE earlier,
  lists the required measurements as "the sound pressure levels in both rooms
  with the source(s) operating, the background noise in the receiving room ...
  and the reverberation times **in the receiving room**". Clause 10, which is
  where the reverberation-time procedures are actually specified, says the same
  thing four times over: its heading is "Reverberation time **in the receiving
  room** (default and low-frequency procedure)", its Clause 10.1 scopes the
  whole clause to "the receiving room", its Clause 10.3 branches on whether
  "the receiving room has a volume larger than or equal to $25\ \text{m}^3$", and its
  Clause 10.4 applies the low-frequency procedure "when **the receiving room**
  volume is smaller than $25\ \text{m}^3$". The phrase is correct two paragraphs
  above, one of them the NOTE,
  where it belongs: the *sound pressure level* really is measured in both rooms
  and its low-frequency procedure really does apply to either. It was carried
  down into the reverberation-time sentence, where only one room exists. The
  other two parts print the same sentence with one room: ISO 16283-2:2020
  Clause 6 and ISO 16283-3:2016 Clause 6 both read "in the receiving room when
  its volume is smaller than $25\ \text{m}^3$", so Part 1 is the outlier of the three.
- **Evidence:** the sentence on PDF page 12 (printed p. 6) of ISO 16283-1:2014,
  identical on PDF page 14 (printed p. 6) of BS EN ISO 16283-1:2014; Clause 10
  and its subclauses on PDF pages 23 and 24 (printed pp. 17 and 18) of the same
  document; and the one-room version of the sentence on PDF page 13 (printed p.
  7) of ISO 16283-2:2020 and PDF page 16 (printed p. 10) of ISO 16283-3:2016.
- **Library behaviour:** the 63 Hz octave substitution is a receiving-room
  operation in every part, following Clause 10; a source-room procedure that
  carries a 63 Hz octave reverberation time is refused, and a source-room call
  takes no reverberation times at all. The corner procedure for the *level*,
  which is the paragraph the phrase belongs to, does admit both rooms in
  ISO 16283-1 and the airborne entry point offers both.
- **Status:** unreported.

## ISO 16283-1:2014, Clause 7.5.3 (a helix that ends "no more than 0,5 m from the ceiling")

- **Location:** Clause 7.5.3 "Helix", first paragraph (printed p. 10).
- **The print:** "The operator holds the microphone or sound level meter with
  outstretched arm at a starting position that is 0,5 m above the floor then
  rotates the body at least twice through 360° from a crouched to a standing
  position, finishing with the microphone at a position that is **no more
  than** 0,5 m from the ceiling."
- **The problem:** the sentence sets a maximum where the same document sets a
  minimum. Clause 7.6 lists "0,5 m between any microphone position and the
  room boundaries" among separation distances that "are minimum values and
  shall be exceeded where possible", and the ceiling is a room boundary. Read
  together, the two leave the end of the helix one height only, exactly 0.5 m
  below the ceiling, which is the height Clause 7.6 asks to exceed. The path
  printed after it carries no such conflict: the cylindrical-type path of
  Clause 7.5.4 rises "until the microphone is 0,5 m from the ceiling", a
  distance with no direction, as is the "0,5 m above the floor" the helix
  itself starts from. ISO 16283-2 carried the same sentence (its first
  edition, in the Spanish translation UNE-EN ISO 16283-2:2016, reads "en una
  posición no más alejada de 0,5 m del techo") until its third edition, whose
  Clause 7.5.5 prints "at a position that is **at least** 0,5 m from the
  ceiling" and whose foreword lists, among the main changes compared to the
  previous edition, "in the helical path (7.5.5) distance of the microphone
  position to the ceiling changed to minimum 0,5 m". The sentence was
  therefore corrected in the impact part and left standing in Part 1, and in
  Part 3: Clause 7.2.3.3 of ISO 16283-3:2016 prints "no more than 0,5 m from
  the ceiling" too. The intended reading is the one ISO 16283-2:2020 now
  prints: the helix ends at least 0.5 m from the ceiling, as Clause 7.6
  requires of every microphone position.
- **Evidence:** a comparison of sentences, each read on its page: Clause 7.5.3
  on PDF page 16 (printed p. 10) and Clause 7.6 on PDF page 18 (printed p. 12)
  of ISO 16283-1:2014, the former identical on PDF page 18 (printed p. 10) of
  BS EN ISO 16283-1:2014; Clause 7.5.5 on PDF page 16 (printed p. 10) and the
  foreword on PDF page 5 (printed p. v) of ISO 16283-2:2020; Clause 7.5.5 on
  PDF page 18 (printed p. 18) of UNE-EN ISO 16283-2:2016; and Clause 7.2.3.3
  on PDF page 18 (printed p. 12) of ISO 16283-3:2016. ISO 16283-1:2014/Amd
  1:2017 was not at hand, so the entry describes the 2014 text and says
  nothing of the amended one.
- **Library behaviour:** no change was required: the library computes from
  band levels and checks no microphone position. The field insulation guide
  quotes both wordings with their clauses and editions, and its drawing of the
  four scanning paths dimensions the end of the helix as 0.5 m from the
  ceiling and writes the two wordings beside it.
- **Status:** unreported.

## ISO 16283-2:2020, Clause 8.3 (a source room in an impact measurement)

- **Location:** Clause 8.3 "Microphone positions", last paragraph (printed p.
  15).
- **The print:** "For the 50 Hz, 63 Hz and 80 Hz one-third octave bands,
  calculate the low-frequency energy-average sound pressure level **for the
  source and/or receiving room** according to 8.5."
- **The problem:** an impact measurement has no source-room sound pressure
  level to calculate. Every other statement of the same procedure in the same
  part names one room: Clause 6 introduces it as used "in the receiving room
  when its volume is smaller than $25\ \text{m}^3$" (printed p. 6), Clause 8.1 repeats "in
  the receiving room" (printed p. 14), Clause 8.5 builds
  $L_\text{i,Corner}$ from corners of the receiving room (printed p. 16), and
  Formulae (1) and (3), which the same sentence sends the reader to, are
  written in $L_\text{i}$, the energy-average impact sound pressure level in
  the receiving room. The phrase is correct where it comes from: ISO 16283-1
  Clause 8.3 says "for the source and/or receiving room" of an airborne
  measurement, where both rooms do carry a level. It was carried across into
  the impact part and survived the revision unchanged.
- **Evidence:** the sentence on PDF page 21 (printed p. 15) of ISO 16283-2:2020
  beside the same sentence on PDF page 23 (printed p. 15) of the ISO/DIS
  16283-2 text circulated as BSI DPC 13/30269186 DC, and the airborne original
  on PDF page 21 (printed p. 15) of ISO 16283-1:2014.
- **Library behaviour:** the impact entry point takes a receiving-room
  low-frequency procedure and nothing else, following Clause 6, 8.1 and 8.5;
  only the airborne entry point, where ISO 16283-1 Clause 8.1 really does admit
  both rooms, offers a source-room one.
- **Status:** unreported.

## ISO 16283-2:2020, Clause 10.3 (a receiving room of exactly $25\ \text{m}^3$)

- **Location:** Clause 10.3 "Default procedure" for the reverberation time
  (printed p. 18).
- **The print:** "for all one-third octave bands between 50 Hz and 5 000 Hz
  when the receiving room has a volume **larger than** $25\ \text{m}^3$ (calculated to the
  nearest cubic metre) and between 100 Hz and 5 000 Hz when the receiving room
  has a volume smaller than $25\ \text{m}^3$ (calculated to the nearest cubic metre)".
- **The problem:** a receiving room that rounds to exactly $25\ \text{m}^3$ falls in
  neither branch, so the clause states no frequency range for it. The other two
  parts print "larger than **or equal to** $25\ \text{m}^3$" in the otherwise identical
  sentence, which closes the boundary. The intended reading is not in doubt:
  the trigger of Clause 8.1 and Clause 10.4 is "smaller than $25\ \text{m}^3$" in all
  three parts, so $25\ \text{m}^3$ belongs to the larger branch and takes the full 50 Hz
  to 5 000 Hz default range.
- **Evidence:** PDF page 24 (printed p. 18) of ISO 16283-2:2020, against PDF
  page 24 (printed p. 18) of ISO 16283-1:2014 and PDF page 24 (printed p. 18)
  of ISO 16283-3:2016, both of which carry the "or equal to". The gap is not a
  2020 slip and not an artefact of a draft: the ISO/DIS text on PDF page 26
  (printed p. 18) of BSI DPC 13/30269186 DC already read the same way, and so
  does the published previous edition, whose Clause 10.3 on PDF page 25
  (printed p. 25) of UNE-EN ISO 16283-2:2016, the Spanish translation of
  ISO 16283-2:2015, reads "un volumen **superior a** $25\ \text{m}^3$" with no "o igual
  a". The wording has stood unchanged across two editions and one revision.
- **Library behaviour:** the trigger predicate is the strict "smaller than
  $25\ \text{m}^3$" the three parts share, so a room of exactly $25\ \text{m}^3$ takes the default
  procedure in every part and no gap exists.
- **Status:** unreported.