# Errata in ISO 11690

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/errata/iso-11690/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/errata/iso-11690/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Errata in ISO 11690: 2 defects in the printed text, with the evidence and what phonometry does about each.

---

These are the 2 entries of the [errata registry](https://docs.jmrp.io/phonometry/reference/errata/) on ISO 11690-3:1998, in the order the registry lists them. The registry's introduction says how each claim is checked against the printed page and what the status of an entry means.

## ISO 11690-3:1998, Table C.2 (a value read off the edge of its own diagram)

- **Location:** Table C.2 on printed page 20 (PDF page 30), against Figure C.1
  on printed page 19 (PDF page 29).
- **The print:** the row for machine M8 gives $L_{W\mathrm{A}} - L_{p\mathrm{A}}$ = 29 dB,
  $\Delta L_\mathrm{A}$ = 10 dB and $L'_{p\mathrm{A}}$ = 88 dB, in a room whose equivalent
  absorption area C.2.2 puts at 195 m2.
- **The problem:** Figure C.1, the diagram the annex says to read $\Delta L_\mathrm{A}$
  off, has a vertical axis that ends at 10 dB, and the curve for a 29 dB
  difference leaves the top of it well before 195 m2. The 10 dB in the table is
  the edge of the diagram rather than a reading of it, and the level it carries
  into the last column is 2.4 dB low.
- **Evidence:** the axis of Figure C.1 runs 0 dB to 10 dB, and the closed form
  the diagram draws, the environmental correction
  $\Delta L_\mathrm{A} = 10 \lg(1 + 4S/A)$ of ISO 3744 with
  $S/S_0 = 10^{(L_{W\mathrm{A}}-L_{p\mathrm{A}})/10}$, gives 12.4 dB for that row. The same
  expression reproduces the other seven rows of the table within 0.4 dB, which
  is the half decibel the diagram is drawn to. Verified on PDF pages 29 and 30
  (printed pp. 19 and 20) of EN ISO 11690-3:1998 as published in
  BS EN ISO 11690-3:1999.
- **Consequence for the standard's own tables:** the last column of that one
  row. Nothing else in the document computes with it.
- **Library behaviour:**
  [`workstation_level_increase`](https://github.com/jmrplens/phonometry/blob/main/src/phonometry/room/workroom_prediction.py)
  evaluates the expression and has no ceiling, so it returns 12.4 dB where the
  table prints 10. The conformance row "ISO 11690-3:1998 Annex C, Figure C.1
  (the eighth machine)" pins it.
- **Status:** not reported.

## ISO 11690-3:1998, Annex B (two workstations whose positions and results are interchanged)

- **Location:** Tables B.5 and B.8 on printed page 18 (PDF page 28), against
  Figure B.1 on printed page 16 (PDF page 26) and the immission columns of
  Tables B.6 and B.9 on printed page 18.
- **The print:** Table B.5 puts workstation W1 at $x$ = 3 m, $y$ = 12 m,
  $z$ = 1,6 m and W2 at 17 m, 4 m, 1,6 m, and Table B.8 repeats those two
  positions for case B. Table B.6 then gives, after the two machines are
  installed, $L_p$ = 82,1 dB at W1 and 80,3 dB at W2; Table B.9 gives 86,2 dB
  at W1 and 85,7 dB at W2 with the first-choice machine, and 83,8 dB and
  82,8 dB with the second. Figure B.1 draws the same two workstations the other
  way round: W1 beside machine M2 on the right of the room, and W2 alone at the
  top left.
- **The problem:** the results belong to the figure's assignment and not to the
  tables'. Machine M2 stands at 17 m, 3 m, 1 m, so the position Table B.5 calls
  W2 is 1.2 m from it and the position it calls W1 is 11.4 m from the nearer
  machine. The far position cannot be the louder of the two, and the
  printed levels say it is. Recomputing case A by the category 1 method the
  annex prescribes, in the 20 m by 15 m by 7 m room of Table B.2 at the mean
  absorption coefficient 0.15 of Table B.3, gives 82.10 dB at 17 m, 4 m, 1.6 m
  and 80.26 dB at 3 m, 12 m, 1.6 m: the two levels Table B.6 prints, each
  against the other workstation's label. Table B.8 contradicts itself on its own
  row, since it prints the far position for W1 and 82 dB, the rounded near
  level, beside it.
- **Evidence:** Figure B.1 with Tables B.2 and B.3 read on PDF page 26 (printed
  p. 16); Table B.4 with the machine positions on PDF page 27 (printed p. 17);
  Tables B.5 to B.9 on PDF page 28 (printed p. 18). All of EN ISO 11690-3:1998
  as published in BS EN ISO 11690-3:1999. Under the figure's assignment the six
  levels of Table B.9 come back within 0.07 dB, and under the tables', the four
  at W1 and W2 miss by 0.48 dB to 1.04 dB (W3 stands in the same place in both)
  while case A misses by 1.8 dB on both rows.
- **Consequence for the standard's own tables:** the Position columns of Tables
  B.5 and B.8 against the labels of Tables B.6 and B.9, in both cases of the
  annex. The prose of case A follows the tables, calling W2 "the workstation of
  M2", so it is on the same side of the contradiction. The numbers themselves
  are right.
- **Library behaviour:** the conformance rows for the two cases of Annex B read
  the printed coordinates and never the labels, and the row "ISO 11690-3:1998
  Annex B, Figure B.1 against Tables B.5 and B.8" records that the results
  reproduce at the positions the figure draws and at no other. The 50 dB of
  background Table B.5 prints against W1 goes with that label rather than with
  the coordinates beside it, so it is heard at the position the figure gives
  W1, next to machine M2. It is worth 0.004 dB: read the other way case A comes
  back 82.09 dB and 80.27 dB instead of 82.10 dB and 80.26 dB, and both
  readings round to the tenth Table B.6 prints.
- **Status:** not reported.
