# Catalogue of resistive facings

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/catalogues/resistive-facings/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/catalogues/resistive-facings/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
Summary: Twenty-nine wire meshes, glass cloths and sintered metal sheets, each with the flow resistance of unit area of it, which is not a resistivity per metre.

---

Twenty-nine thin resistive facings, the wire meshes, glass cloths and sintered
metal sheets that go over a porous absorber or across the mouth of a cavity,
each with the flow resistance of unit **area** of it. That is the thing this
table is most likely to be misread for. The [porous
catalogue](https://docs.jmrp.io/phonometry/reference/catalogues/porous-materials/) holds a flow
**resistivity**, per metre of the bulk material it describes; a facing is a
sheet with no thickness worth dividing by, so what is measured on it is a
resistance in pascal seconds per metre, and the two quantities are a thickness
apart. Multiplying one of these rows by a thickness gives a number nobody
measured.

Two of the three tables print that resistance twice, once as the page's N s/m³
and once as a multiple of the characteristic impedance of air, and neither says
what it took the impedance to be. Both columns are kept as printed rather than
one being recomputed from the other, because dividing them gives the impedance
back: the wire meshes imply 407 to 421 Pa s/m and the sintered sheets 400,
except for the one block that implies 397.7, which is a property of the page
and not of any facing. The sintered sheets are
also the only rows with a nonlinearity factor, the ratio of the resistances
measured at face velocities of 500 and 20 cm/s, and they run from 1.8 to 5: a
facing at 1 would be the linear one the rest of this library assumes. The
others are named by what a weaver would call them, a wire count or a weave, and
the search matches a bare number because that is what a glass cloth is called.

Each value is the number its page prints, unless a word in brackets after it says what else it is:

- **carried**: the page gives this value on another of its rows
- **bound**: the page prints a bound and no value

A note mark after a name or a value points to the note the page makes about that row or cell, listed under the table.

| Facing | Weave | Specific flow resistance (Pa·s/m) | Normalized flow resistance | Wires per centimetre (1/cm) | Wire diameter (µm) | Thickness (mm) | Mass per unit area (kg/m²) | Surface density (g/m²) | Nonlinearity factor | Source |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 12 |  | 5.7 | 0.014 | 12 | 330 |  | 1.6 |  |  | Vér & Beranek 2e TABLE 8.5, PDF page 266 (printed p. 262) |
| 20 |  | 5.9 | 0.014 | 20 | 220 |  | 1.2 |  |  | Vér & Beranek 2e TABLE 8.5, PDF page 266 (printed p. 262) |
| 40 |  | 9 | 0.022 | 40 | 115 |  | 0.63 |  |  | Vér & Beranek 2e TABLE 8.5, PDF page 266 (printed p. 262) |
| 47 |  | 13.5 | 0.033 | 47 | 90 |  | 0.48 |  |  | Vér & Beranek 2e TABLE 8.5, PDF page 266 (printed p. 262) |
| 80[^flowResistance-1] |  | 24.6 | 0.06 | 80 | 57 |  | 0.31 |  |  | Vér & Beranek 2e TABLE 8.5, PDF page 266 (printed p. 262) |
| 120[^flowResistance-2] | 60 × 58 | 300 |  |  |  |  |  | 96 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 126[^flowResistance-3] | 34 × 32 | 45 |  |  |  |  |  | 164 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 138[^flowResistance-4] | 64 × 60 | 2 200 |  |  |  |  |  | 204 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 181[^flowResistance-5] | 57 × 54 | 380 |  |  |  |  |  | 272 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1044[^flowResistance-6] | 14 × 14 | 36 |  |  |  |  |  | 585 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1544[^flowResistance-7] | 14 × 14 | 19 |  |  |  |  |  | 535 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 3862[^flowResistance-8] | 20 × 38 | 350 |  |  |  |  |  | 375 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1658[^flowResistance-9] | 24 × 24 | 10 |  |  |  |  |  | 57 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1562[^flowResistance-10] | 30 × 16 | < 5 (bound)[^flowResistance-11] |  |  |  |  |  | 59 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1500[^flowResistance-12] | 16 × 14 | 13 |  |  |  |  |  | 293 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1582[^flowResistance-13] | 60 × 56 | 400 |  |  |  |  |  | 442 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1584[^flowResistance-14] | 42 × 36 | 200 |  |  |  |  |  | 750 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| 1589[^flowResistance-15] | 13 × 12 | 11 |  |  |  |  |  | 366 |  | Vér & Beranek 2e TABLE 8.6, PDF page 267 (printed p. 263) |
| FM 125[^flowResistance-16] |  | 100 | 0.25 |  |  | 1 | 3.9 |  | 3.6 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| FM 127[^flowResistance-16] |  | 100 (carried)[^flowResistance-17] | 0.25 (carried)[^flowResistance-18] |  |  | 0.76 | 3.3 |  | 5 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| FM 185[^flowResistance-16] |  | 100 (carried)[^flowResistance-17] | 0.25 (carried)[^flowResistance-18] |  |  | 0.5 | 2 |  | 2.6 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| 347-10-20-AC3A-A[^flowResistance-16] |  | 100 (carried)[^flowResistance-17] | 0.25 (carried)[^flowResistance-18] |  |  | 0.5 | 1.32 |  | 2 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| 347-10-30-AC3A-A[^flowResistance-16] |  | 100 (carried)[^flowResistance-17] | 0.25 (carried)[^flowResistance-18] |  |  | 0.76 | 1.1 |  | 2 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| FM 802[^flowResistance-19] |  | 100 (carried)[^flowResistance-17] | 0.25 (carried)[^flowResistance-18] |  |  | 0.5 | 1.3 |  | 2 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| FM 134[^flowResistance-16] |  | 350 | 0.88 |  |  | 0.89 | 3.8 |  | 4.7 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| FM 122[^flowResistance-16] |  | 500 | 1.25 |  |  | 0.76 | 1.4 |  | 1.8 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| FM 126[^flowResistance-16] |  | 500 (carried)[^flowResistance-20] | 1.25 (carried)[^flowResistance-21] |  |  | 0.66 | 3.7 |  | 3.6 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| FM 190[^flowResistance-16] |  | 500 (carried)[^flowResistance-20] | 1.25 (carried)[^flowResistance-21] |  |  | 0.41 | 2 |  | 3.3 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |
| 347-50-30-AC3A-A[^flowResistance-16] |  | 500 (carried)[^flowResistance-20] | 1.25 (carried)[^flowResistance-21] |  |  | 0.76 | 1.4 |  | 2 | Vér & Beranek 2e TABLE 8.7, PDF page 267 (printed p. 263) |

[^flowResistance-1]: The page prints this mass twice, 0.31 kg/m2 and 0.63 lb/ft2, and 0.63 lb/ft2 is 3.08 kg/m2, ten times the first. The defective cell is the pound one, the restatement, which this catalogue does not hold; the row serves the 0.31 kg/m2 that the column above it and the weave of the mesh both support. See docs/ERRATA.md.
[^flowResistance-2]: The page prints this surface density twice, 3.16 oz/yd2 and 96 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.6 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-3]: The page prints this surface density twice, 5.37 oz/yd2 and 164 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.0 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-4]: The page prints this surface density twice, 6.70 oz/yd2 and 204 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.4 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-5]: The page prints this surface density twice, 8.90 oz/yd2 and 272 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 10.9 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-6]: The page prints this surface density twice, 19.2 oz/yd2 and 585 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.3 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-7]: The page prints this surface density twice, 17.7 oz/yd2 and 535 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 12.2 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-8]: The page prints this surface density twice, 12.3 oz/yd2 and 375 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.2 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-9]: The page prints this surface density twice, 1.87 oz/yd2 and 57 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.2 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-10]: The page prints this surface density twice, 1.94 oz/yd2 and 59 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.5 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-11]: the page prints an upper bound of 5 and no value
[^flowResistance-12]: The page prints this surface density twice, 9.60 oz/yd2 and 293 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.1 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-13]: The page prints this surface density twice, 14.5 oz/yd2 and 442 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.2 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-14]: The page prints this surface density twice, 24.6 oz/yd2 and 750 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.2 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-15]: The page prints this surface density twice, 12.0 oz/yd2 and 366 g/m2, and one ounce per square yard is 33.906 grams per square metre to three decimals, by the exact definitions of the ounce and the yard, so the two printings are 11.2 per cent apart. The whole column is, by the same factor; the page does not say which of its two columns carries it, so this row holds the g/m2 as printed and docs/ERRATA.md argues the pair. Footnote a: “Averaged over a large sample.”
[^flowResistance-16]: Type 347 stainless steel, per footnote a. The flow resistance is for air at 70°F, per the column spanner, “Specific Flow Resistance Air, 70°F”.
[^flowResistance-17]: carried down the blank cells of TABLE 8.7 from the FM 125 row, which prints 100 N s/m3 for the six rows of its block
[^flowResistance-18]: carried down the blank cells of TABLE 8.7 from the FM 125 row, which prints 0.25 times rho0 c0 for the six rows of its block
[^flowResistance-19]: Hastelloy X, the one material footnote a excepts. The flow resistance is for air at 70°F, per the column spanner, “Specific Flow Resistance Air, 70°F”.
[^flowResistance-20]: carried down the blank cells of TABLE 8.7 from the FM 122 row, which prints 500 N s/m3 for the four rows of its block
[^flowResistance-21]: carried down the blank cells of TABLE 8.7 from the FM 122 row, which prints 1.25 times rho0 c0 for the four rows of its block

## References

- **Vér, I. L., & Beranek, L. L. (2006).** *Noise and vibration control engineering: Principles and applications* (2nd ed.). Wiley. https://doi.org/10.1002/9780470172568
  Tables 8.5 to 8.7: the source of the rows of the catalogue of resistive facings that cite it.