# Catalogue of fluids

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/reference/catalogues/fluids/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/reference/catalogues/fluids/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-10-28
Updated: 2026-11-16T21:36:14Z
Summary: Named fluid states: liquids and gases at the temperature each page states, read from two books, and four airs fixed by the models and standards that use them.

---

Every named fluid state this library carries. The twenty-one read from a page
are in `fluids.PUBLISHED_FLUIDS`: three from Bies and eighteen liquids and
gases from Norton & Karczub, each at the temperature its page states and with
the ratio of specific heats where the page prints one. The four airs below
them sit elsewhere in the tree,
each beside the model or the standard that fixes it, and they disagree because
each is the air its own document assumes.

Each value is the number its page prints, unless a word in brackets after it says what else it is:

- **fixed**: what the model or the standard beside it fixes

A note mark after a name or a value points to the note the page makes about that row or cell, listed under the table.

| State | Conditions | Speed of sound (m/s) | Density (kg/m³) | Viscosity (µPa·s) | Heat capacity ratio | What fixes it |
| --- | --- | --- | --- | --- | --- | --- |
| Air | 20 °C, 101 325 Pa | 343 | 1.206 |  |  | Air as printed in Bies 5e Table C.1, PDF page 746 (printed p. 717) |
| Fresh water | 20 °C, 101 325 Pa | 1 497 | 998 |  |  | Fresh water as printed in Bies 5e Table C.1, PDF page 746 (printed p. 717) |
| Sea water | 13 °C, 101 325 Pa | 1 530 | 1 025 |  |  | Sea water as printed in Bies 5e Table C.1, PDF page 746 (printed p. 717) |
| Castor oil | 20 °C, 101 325 Pa | 1 540 | 950 |  |  | Castor oil as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Ethyl alcohol | 20 °C, 101 325 Pa | 1 150 | 790 |  |  | Ethyl alcohol as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Fresh water | 20 °C, 101 325 Pa | 1 483 | 998 |  | 1.004 | Fresh water as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Fresh water | 13 °C, 101 325 Pa | 1 441 | 998 |  | 1.004 | Fresh water as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Glycerin | 20 °C, 101 325 Pa | 1 980 | 1 260 |  |  | Glycerin as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Mercury | 20 °C, 101 325 Pa | 1 450 | 13 600 |  | 1.13 | Mercury as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Petrol | 20 °C, 101 325 Pa | 1 390 | 680 |  |  | Petrol as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Sea water | 13 °C, 101 325 Pa | 1 500 | 1 026 |  | 1.01 | Sea water as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Turpentine | 20 °C, 101 325 Pa | 1 250 | 870 |  | 1.27 | Turpentine as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Air | 0 °C, 101 325 Pa | 332 | 1.293 |  | 1.402 | Air as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Air | 20 °C, 101 325 Pa | 343 | 1.21 |  | 1.402 | Air as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Carbon dioxide | 20 °C, 101 325 Pa | 267 | 1.84 |  | 1.4 | Carbon dioxide as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Hydrogen | 0 °C, 101 325 Pa | 1 270 | 0.084[^fluids-1] |  | 1.41 | Hydrogen as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Hydrogen | 20 °C, 101 325 Pa | 1 330 | 0.084[^fluids-1] |  | 1.41 | Hydrogen as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Nitrogen | 20 °C, 101 325 Pa | 349 | 1.17 |  | 1.4 | Nitrogen as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Oxygen | 0 °C, 101 325 Pa | 317 | 1.43[^fluids-1] |  | 1.4 | Oxygen as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Oxygen | 20 °C, 101 325 Pa | 326 | 1.43[^fluids-1] |  | 1.4 | Oxygen as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Steam | 100 °C, 101 325 Pa | 405 | 0.6 |  | 1.324 | Steam as printed in Norton & Karczub 2e Appendix 4 B and C, PDF page 626 (printed p. 606) |
| Air | 23 °C, 101 325 Pa | 345.86652 (fixed) | 1.1860848 (fixed) |  | 1.4007573 (fixed) | IEC 61094-2:2009 Annex F (CIPM-2007) at the ISO 9053-2:2020 Annex A.3 reference state |
| Air | 20 °C, 101 325 Pa | 340 (fixed) | 1.29 (fixed) |  |  | EN/ISO 12354 Annex A speed of sound with the Annex B air density |
| Air | 20 °C, 101 325 Pa | 343 (fixed) | 1.205 (fixed) | 18.4 (fixed) | 1.4 (fixed) | textbook dry air at 20 degC, the absorber models' default medium |
| Air | 20 °C, 101 325 Pa | 343 (fixed) | 1.2 (fixed) |  |  | air at room conditions, the acoustic solver's default medium |

[^fluids-1]: The appendix prints the same density for this substance at both temperatures it lists, while the speed beside it changes as a speed should. Air, in the same part of the same table, does drop from 1.293 to 1.21 kg/m3 over the same interval, so the repetition here is the table departing from its own practice. It is served exactly as printed: the ideal-gas relation P = rho c^2 / gamma applied to these three columns puts this row between 96 and 109 kPa, which is no further from an atmosphere than the carbon dioxide and steam rows that nobody disputes, so nothing in the document settles which of the two densities was meant.

## References

- **Bies, D. A., Hansen, C. H., & Howard, C. Q. (2017).** *Engineering noise control* (5th ed.). CRC Press. https://doi.org/10.1201/9781351228152
  Table C.1: the source of the rows of the catalogue of fluids that cite it.
- **International Electrotechnical Commission. (2009).** [*Electroacoustics — Measurement microphones — Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique*](https://webstore.iec.ch/en/publication/4486) (IEC 61094-2:2009).
  Annex F: the CIPM-2007 equations the IEC 61094-2 air of the catalogue of fluids is computed with, at the reference state of ISO 9053-2:2020 Annex A.3.
- **International Organization for Standardization. (2017).** [*Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 1: Airborne sound insulation between rooms*](https://www.iso.org/standard/70242.html) (ISO 12354-1:2017).
  Annexes A and B: the speed of sound of Annex A and the air density of the Annex B model, which the EN/ISO 12354 air of the catalogue of fluids holds.
- **Norton, M. P., & Karczub, D. G. (2003).** *Fundamentals of noise and vibration analysis for engineers* (2nd ed.). Cambridge University Press. https://doi.org/10.1017/CBO9781139163927
  Appendix 4, parts B and C: the source of the rows of the catalogue of fluids that cite it.