Psychoacoustic fluctuation strength per ECMA-418-2:2025 (4th ed., Clause 9).

Clean-room implementation of the fluctuation-strength signal chain of
ECMA-418-2:2025 (Clause 9, Sottek Hearing Model). The shared auditory
front-end (Clause 5: outer/middle-ear filter, 53-band auditory filter bank,
compressive nonlinearity of Formulae 23-25) is reused from
[`phonometry.psychoacoustics.loudness.ecma`](/phonometry/reference/api/psychoacoustics/ecma/); this module adds the
fluctuation-strength chain, which mirrors the roughness chain of Clause 7 but
replaces the DFT-based envelope analysis with High-resolution Spectral
Analysis (HSA):

* fluctuation-strength zero-padding (Clause 5.1.2.2) and segmentation
  (Clause 5.1.5.2) with the fixed block/hop $s_\mathrm{b} = 65536$ /
  $s_\mathrm{h} = 16384$
  (Clause 9.1.1);
* the Hilbert envelope of each critical-band block and a factor-32
  downsampling to 1500 Hz (Clause 9.1.2, Formula 119);
* the envelope-dependent analysis windows with quieter-period detection
  (Clause 9.1.3, Formula 120);
* the HSA of the windowed envelopes -- a least-squares fit of window-kernel
  spectral line pairs to the k = 0..48 DFT bins (Clause 9.1.4,
  Formulae 121-142);
* the identification of prominent spectral line pairs from the local maxima
  of the power spectrum and the local minima of the HSA error over a
  logarithmic modulation-rate grid (Clause 9.1.5, Formulae 143-146);
* the band-pass modulation-rate weighting (Clause 9.1.6, Formulae 147-148),
  the damped-Newton fine tuning of the dominant modulation rate
  (Clause 9.1.7, Formulae 149-152), the harmonic analysis (Clause 9.1.8,
  Formulae 153-156) and the centre-of-gravity weighting (Clause 9.1.9,
  Formulae 157-158);
* the scaling with the HSA-based specific loudness (Clause 9.1.10,
  Formulae 159-161); and
* the interpolation to 50 Hz, the distribution-dependent nonlinear transform
  with the calibration constant `c_F`, the first-order smoothing
  (Clause 9.1.11, Formulae 162-168) and the aggregation into the average
  specific fluctuation strength F'(z) (Clause 9.1.12), the time-dependent
  fluctuation strength F(l50) (Clause 9.1.13, Formula 169) and the
  representative 90th-percentile single value F (Clause 9.1.14).

The API is monaural: the quadratic-mean binaural combination of
Formula (170) (Clause 9.1.15) is not implemented -- analyse each channel
separately.

The calibration constant `c_F` of Formula (163) is the standard's tabulated
value (not reverse-fit), and the chain reproduces the Clause 9 reference
point: a 1 kHz carrier 100 %-amplitude-modulated at 4 Hz with an overall
sound pressure level of 60 dB SPL converges to 0.9958 vacil_HMS against the
defined 1 vacil_HMS as the 90th percentile settles (0.9931 for a 5 s signal,
0.9957 at 8 s, 0.9958 by 12 s). Footnote 47 allows a +/-0.25 % adjustment
of c_F, which is not used. The level convention follows Clause 7/9 as
established for the roughness metric: the stated 60 dB is the overall RMS
level of the modulated signal, not the carrier level.

Clause 9 interpretation notes (all resolved by internal consistency and
pinned by the calibration signal; the confirmed defects are recorded in
`docs/ERRATA.md`):

* Formula (127) prints the phase factor
  $\exp(-j 2\pi f_n (\tilde{s}_\mathrm{b} - n_\mathrm{ze} + n_\mathrm{zb} - 1))$; the DFT of
  the rectangular analysis window requires $\pi$
  in place of $2\pi$ (with $2\pi$ the HSA cannot reproduce the
  very
  spectra it fits, breaking the exact-recovery property claimed for it).
* Formula (144) subtracts 1 from the three-bin centroid before scaling by
  `delta_f`; with the 0-based bin convention stated below Formula (122)
  (bin k maps to $k \tilde{r}_\mathrm{s} / \tilde{s}_\mathrm{b}$) that offset shifts
  every modulation
  rate one bin low, so the centroid is used without the offset.
* Clause 9.1.7 states the Newton constants (differential step 1e-5, damped
  step cap 2e-4, stop tolerance 1e-7) without units; read in Hz they cap the
  total displacement at 2e-3 Hz, which makes the fine tuning inert and the
  failure check against 1.25 * delta_f (~0.92 Hz) unreachable. They are
  self-consistent as normalized frequencies (f / r~_s), which is how this
  module applies them.
* The amplitude of a spectral line pair (Formulae 146-147, 155, 157-160) is
  taken as the squared magnitude of the half-line solution components of
  Formula (123), $x_{2m}^2 + x_{2m+1}^2 = |\hat{p}_m|^2 / 4$: with
  that reading
  Formula (160) is exactly the RMS of the modelled band signal (the loudness
  chain of Formulae 22-23 applied to the harmonic complex) and the tabulated
  c_F reproduces the calibration signal.
* The \< 0.125 Hz discard of Clause 9.1.7 names `f_c,1,opt`; it is applied
  here to the rate that survives the failure check (the original
  `f~_c,imax` when the fine tuning was cancelled), since discarding a
  block on a diverged optimizer output would drop healthy modulation.
* For signals shorter than the ~0.74 s transient (fewer than 37 frames at
  50 Hz), the Clause 9.1.12/9.1.14 discard of l50 = 0..35 would leave no
  frames; the aggregation then falls back to all frames instead of
  reporting an empty (zero) result.

> Auto-generated from the source docstrings by `scripts/generate_api_docs.py` (`make api-docs`). Do not edit by hand.

## EcmaFluctuationStrength

```python
EcmaFluctuationStrength(
    fluctuation_strength: float,
    specific_fluctuation_strength: np.ndarray,
    bark: np.ndarray,
    centre_frequencies: np.ndarray,
    times: np.ndarray,
    fluctuation_strength_vs_time: np.ndarray,
    specific_fluctuation_strength_vs_time: np.ndarray,
    field: str,
)
```

Result of an ECMA-418-2:2025 (Sottek) fluctuation-strength calculation.

`fluctuation_strength` is the single representative fluctuation
strength F in vacil_HMS (the 90th percentile of F(l50), Clause 9.1.14).
`specific_fluctuation_strength` is the average specific fluctuation
strength F'(z) in vacil_HMS/Bark_HMS over the 53 auditory bands
(Clause 9.1.12), with `bark` the critical-band-rate scale z
(0.5..26.5 Bark_HMS) and `centre_frequencies` the band centre
frequencies F(z). `times` and `fluctuation_strength_vs_time` hold the
time-dependent fluctuation strength F(l50) at 50 Hz (Formula 169);
`specific_fluctuation_strength_vs_time` is the time-dependent specific
fluctuation strength F'(l50, z) (Formula 168) of shape
`(n_times, 53)`. `field` records the assumed sound field.

### EcmaFluctuationStrength.plot()

```python
EcmaFluctuationStrength.plot(
    ax: Axes | None = None,
    *,
    language: str = 'en',
    **kwargs: Any,
) -> Axes | np.ndarray
```

Plot the fluctuation-strength result (see `phonometry._plot.psychoacoustics`).

Draws the time-dependent fluctuation strength F(l50) and a
specific-fluctuation-strength heatmap. Requires matplotlib
(`pip install phonometry[plot]`).

## fluctuation_strength_ecma

```python
fluctuation_strength_ecma(
    signal_in: Signal | np.ndarray,
    fs: float | None = None,
    field: Literal['free', 'diffuse'] = 'free',
) -> EcmaFluctuationStrength
```

Psychoacoustic fluctuation strength per ECMA-418-2:2025 (Clause 9).

**Parameters**

| Name | Description |
| :--- | :--- |
| `signal_in` | Calibrated sound pressure signal in pascals. Accepts a [`phonometry.io.Signal`](/phonometry/reference/api/io/io/#signal), which is where "calibrated" comes from without arithmetic: this model reads absolute levels, so an uncalibrated record is taken as if one digital unit were one pascal and the answer is wrong by however far that is from true. |
| `fs` | Sampling rate in Hz. Signals not at 48 kHz are resampled (Clause 5.1.1). Required for a bare array; a [`Signal`](/phonometry/reference/api/io/io/#signal) brings its own, and an explicit value that disagrees with it raises instead of silently winning. |
| `field` | `"free"` (default) or `"diffuse"` sound field, selecting the outer/middle-ear filter of Clause 5.1.3. |

**Returns:** An [`EcmaFluctuationStrength`](/phonometry/reference/api/psychoacoustics/fluctuation-strength-ecma/#ecmafluctuationstrength) with the single value F (Clause 9.1.14), the average specific fluctuation strength F'(z) (Clause 9.1.12) and the time-dependent fluctuation strength F(l50) (Formula 169).

**Raises**

| Exception | When |
| :--- | :--- |
| ValueError | for an empty, multichannel or non-finite signal, a non-finite or non-positive `fs`, or an unknown `field`. |

A 1 kHz carrier 100 %-amplitude-modulated at 4 Hz with an overall level
of 60 dB SPL yields 1 vacil_HMS (Clause 9 calibration; reproduced to
0.9958 vacil_HMS with the tabulated c_F of Formula (163) once the 90th
percentile settles, by a 12 s signal).