# Sound power and intensity

The central quantity of this section is the **sound power**: the total
acoustic energy per second a source radiates. Expressed in decibels as the
sound power level, it is the figure that goes on a datasheet, feeds a room or
outdoor prediction and is checked against noise-emission limits.

[Sound Power](https://docs.jmrp.io/phonometry/devices/sound-power/) chooses between the
standardised routes and closes the job with the ISO 4871 emission
declaration, and each route has its own page:
[Sound Power by Pressure Methods](https://docs.jmrp.io/phonometry/devices/sound-power-pressure/)
for the enveloping surface of ISO 3744/3746 and the precision anechoic grade
of ISO 3745, whose room the guide
[Free Field and Reference Sources](https://docs.jmrp.io/phonometry/devices/free-field-qualification/)
qualifies by ISO 26101, beside the ISO 6926 calibration of the reference
source every comparison method needs,
[Sound Power in the Reverberation Room](https://docs.jmrp.io/phonometry/devices/sound-power-reverberation/)
for the direct and comparison methods of ISO 3741,
[Sound Power in Small Test Rooms](https://docs.jmrp.io/phonometry/devices/sound-power-test-rooms/)
for the two ISO 3743 rooms for small movable sources, hard-walled with a
reference sound source or specially reverberant,
[Sound Power in Situ by Comparison](https://docs.jmrp.io/phonometry/devices/sound-power-in-situ/)
for the ISO 3747 comparison against a reference sound source where the
machine works,
[Sound Power in a Duct](https://docs.jmrp.io/phonometry/devices/sound-power-in-duct/)
for the ISO 5136 in-duct method that measures a fan inside its own test duct,
[Sound Power of Multisource Industrial Plants](https://docs.jmrp.io/phonometry/devices/sound-power-plant/)
for the ISO 8297 contour round a whole plant, a quarry or a petrochemical
complex,
[Sound Power in the 16 kHz Octave](https://docs.jmrp.io/phonometry/devices/sound-power-high-frequency/)
for the ISO 9295 methods that carry the reverberation room and the free
field above 10 kHz,
[Sound Power of Steam Turbine Sets](https://docs.jmrp.io/phonometry/devices/sound-power-turbines/)
for the IEC 61063 test code that measures a turbine set in its own hall, and
[Sound Power by Intensity Scanning](https://docs.jmrp.io/phonometry/devices/sound-power-intensity/)
for the on-site scanning of ISO 9614-2 and its ISO 9614-3 precision grade, and
[Sound Intensity](https://docs.jmrp.io/phonometry/devices/intensity/)
for the discrete-point power summation of ISO 9614-1, which stands still at
each position rather than sweeping the surface.

One route does not measure sound at all.
[Sound power from surface vibration (ISO/TS 7849)](https://docs.jmrp.io/phonometry/devices/vibration-sound-power/)
estimates the radiated power from the surface-averaged velocity level and a
radiation factor, which is what remains when the machine cannot be moved to a
qualified room and its environment is too noisy for an enveloping surface:
Part 1 gives an upper-limit value from the velocity alone, Part 2 an
engineering value once the radiation factor has been estimated properly. It
also answers a slightly different question from the acoustic routes: it
characterises what the *structure* radiates, and stays blind to sound escaping
through openings, intakes and outlets, and it is the natural bridge to the
structure-borne pages, since the same surface velocity is what
[Vibration and structure-borne sound](https://docs.jmrp.io/phonometry/vibration/) measures.

The sound power level is not, however, what the person operating the machine
is exposed to. That is the **emission sound pressure level** at the work
station, the number the ISO 4871 declaration prints beside the power level and
the Machinery Directive asks for above 70 dB(A).
[Emission Sound Pressure at a Work Station](https://docs.jmrp.io/phonometry/devices/workstation-emission/)
covers the ISO 11200 group that determines it: the same reading less a
background correction and a correction for the reflections the room sent back.

Behind the intensity-based routes sits **sound intensity** itself: the signed
power flux that can localise sources and separate them from background noise,
measured with a two-microphone probe per IEC 61043 and qualified by the
ISO 9614-1 field indicators, covered in
[Sound Intensity (p-p)](https://docs.jmrp.io/phonometry/devices/intensity/).

If you are here to measure a machine, start with
[Sound Power](https://docs.jmrp.io/phonometry/devices/sound-power/) and let its decision guidance
pick the route; read [Sound Intensity (p-p)](https://docs.jmrp.io/phonometry/devices/intensity/)
when that route involves an intensity probe, and go to
[Sound power from surface vibration](https://docs.jmrp.io/phonometry/devices/vibration-sound-power/)
when the machine cannot leave its installation and the background is too high
for any pressure method. The determined power level is what the quieting
measures of the [Noise control](https://docs.jmrp.io/phonometry/noise-control/) pages are
judged against.

## Pages in this section

- [Sound Intensity (p-p)](https://docs.jmrp.io/phonometry/devices/intensity/): two-microphone
  sound intensity per IEC 61043, with the ISO 9614-1 field indicators and its
  sound power determination at discrete points.
- [Sound Power](https://docs.jmrp.io/phonometry/devices/sound-power/): choosing the determination
  method and declaring the noise emission per ISO 4871.
- [Sound Power by Pressure Methods](https://docs.jmrp.io/phonometry/devices/sound-power-pressure/):
  the enveloping surface of ISO 3744/3746 and the precision anechoic grade of
  ISO 3745, and the sound energy level of a burst over the ISO 3744/3746
  enveloping surface.
- [Free Field and Reference Sources](https://docs.jmrp.io/phonometry/devices/free-field-qualification/):
  the ISO 26101 qualification of an anechoic or hemi-anechoic room against the
  Annex A that Amendment 1:2017 wrote into ISO 3745, and the calibration and
  requirements of an ISO 6926 reference sound source.
- [Sound Power in the Reverberation Room](https://docs.jmrp.io/phonometry/devices/sound-power-reverberation/):
  the direct and comparison methods of ISO 3741, for sound power and for the
  sound energy of a single event.
- [Sound Power in Small Test Rooms](https://docs.jmrp.io/phonometry/devices/sound-power-test-rooms/):
  the ISO 3743-1 comparison against a reference sound source in a
  hard-walled room and the ISO 3743-2 direct and comparison methods in a
  special reverberation room, for small movable sources, with the room
  qualification of both and the sound energy level of a burst.
- [Sound Power in Situ by Comparison](https://docs.jmrp.io/phonometry/devices/sound-power-in-situ/):
  the ISO 3747 engineering and survey comparison against a reference sound
  source in a reverberant environment, for the machine that cannot leave its
  installation, with the sound energy level of an impulsive source.
- [Sound Power in a Duct](https://docs.jmrp.io/phonometry/devices/sound-power-in-duct/):
  the ISO 5136 in-duct method for fans, with the sampling-tube flow and
  modal correction of Annex A and the plane-wave relation.
- [Sound Power of Multisource Industrial Plants](https://docs.jmrp.io/phonometry/devices/sound-power-plant/):
  the ISO 8297 engineering method for a whole industrial plant, measured
  round a contour drawn on the plot plan, with the proximity and air
  absorption terms of clause 10 and the uncertainty of Table 1.
- [Sound Power in the 16 kHz Octave](https://docs.jmrp.io/phonometry/devices/sound-power-high-frequency/):
  the ISO 9295 methods for the octave band above 10 kHz, with the room
  constant from the reverberation time or from the air absorption of
  Annex A, the comparison for tones and the free-field correction.
- [Sound Power of Steam Turbine Sets](https://docs.jmrp.io/phonometry/devices/sound-power-turbines/):
  the IEC 61063 test code for a steam turbine set and its driven
  machinery, with the stepped surface 1 m out, the key positions of
  Figure 2, the background correction of Table 2, the environmental
  correction of Figure A.3 and the report of clause 10.
- [Sound power from surface vibration (ISO/TS 7849)](https://docs.jmrp.io/phonometry/devices/vibration-sound-power/):
  the radiated power from the surface-averaged velocity level and the
  radiation factor, with the Part 1 upper limit and the Part 2 engineering
  value.
- [Sound Power by Intensity Scanning](https://docs.jmrp.io/phonometry/devices/sound-power-intensity/):
  the on-site scanning of ISO 9614-2 and the ISO 9614-3 precision grade.
- [Emission Sound Pressure at a Work Station](https://docs.jmrp.io/phonometry/devices/workstation-emission/):
  the ISO 11200 group, which turns a reading at the operator's position into
  what the machine alone puts there, with the background and local
  environmental corrections and the grade each earns.

## What this section does not cover

The determination methods start after the facility and the probe have been
qualified. The free-field qualification of an anechoic or hemi-anechoic room
is performed, by ISO 26101 against the amended ISO 3745 Annex A, in
[Free Field and Reference Sources](https://docs.jmrp.io/phonometry/devices/free-field-qualification/),
and so are the room checks of ISO 3743, in
[Sound Power in Small Test Rooms](https://docs.jmrp.io/phonometry/devices/sound-power-test-rooms/): the volume, surfaces
and acoustic adequacy of the hard-walled room of Part 1
(`check_hard_walled_room`) and the reverberation time, surfaces and
suitability of the special reverberation room of Part 2
(`check_special_room_reverberation`, `check_special_room_surfaces`,
`check_special_room_suitability`).
ISO 3741's reverberation-room qualification (eigenfrequency counting or a
reference-source comparison) and the IEC 61043 residual-intensity test of a
probe-and-analyser chain are **assumed, not performed**: the library warns
on the coarse advisory criteria the standards state explicitly (the Table 1
minimum volume, the position count, an inter-position spread above 1.5 dB, the
ISO 3744 K₂ validity) and grades a residual-intensity index you measured
yourself. The C₃ meteorological correction of ISO 3745 likewise needs an
air-absorption coefficient you supply; it is not computed from ISO 9613-1
here.

One route stops short of its standard: on the vibration route, the measurement
clauses 5 to 7 of both parts of ISO/TS 7849 are laboratory practice rather
than code, and only the single-machine radiation factor of Formula 8 is
implemented, so a batch or family determination needs an already-averaged
value. And nothing here reduces a machine's emission: quieting a source is
[Noise control](https://docs.jmrp.io/phonometry/noise-control/), and a declared