# CPU-bound core

One saturated core of a MikroTik RB5009 read at 10 Hz: why the device total hides it, the scheduler moving the load between cores, and the temperature.

Source: https://docs.jmrp.io/mikroscope/playbooks/cpu/

**In short:** one saturated core on the four-core RB5009 reads as about 29 % of
the device, so it is the per-core row, not the total, that shows a
single-threaded bottleneck: here one core at 99.8 % while three idled. At 10 Hz
the scheduler moving the load between cores is visible for about 20 s before it
settles; sampled once a second, that is a vague plateau. The load was provoked
on purpose.

Measured on RB5009UG+S+ · 4 × 1.4 GHz Cortex-A72 · RouterOS 7.24.2 · Linux 5.6.3 · 2026-09-12 · agent at 10 Hz in an ephemeral privileged container

## Setup

A console loop that burns one core and ends on its own, with no configuration
change and no external dependency:

```routeros
:local i 0; :while ($i < 4000000) do={ :set i ($i + 1) }
```

It ran 58.8 s.

## Recording

In 5-second buckets. The agent ships raw tick deltas; the percentages below were
computed from them afterwards. There is no chart: the run predates the history
of the reference InfluxDB store, which begins on 2026-09-19.

```text
   t  busy%   per-core busy%          ctxt/s  temp   MHz
   0   22.3   31.8   7.4  40.4   9.6    9192  36.5  1400
   1   30.9   11.7  11.4  89.7  10.6   11325  37.0  1400
   2   29.9   14.3   9.4  19.6  76.0    9476  37.0  1400
   3   29.1    7.4   9.4  17.6  81.6   10805  37.0  1400
   4   29.3    3.1   9.4   4.9  99.8    9257  37.2  1400
   8   28.4    2.2   7.0   4.6  99.8   11947  37.2  1400
  11   33.0   11.8  11.2   9.0  99.7   12222  37.3  1400
```

## What to look at

- **Total ~29 % is one core of four.** A device total is a trap; always look at
  the per-core row. "29 % CPU" here means "one core is saturated and three are
  idle", which for a single-threaded bottleneck is the whole story.
- **The scheduler took ~20 s to settle.** Buckets 0–3 show the work moving
  between cores (40 % → 90 % → 76 % → 82 %) before pinning on core 3 at 99.8 %.
  If you sample at 1 s or slower you see a vague plateau; at 10 Hz you see the
  migration.
- **Temperature followed: 36.5 → 37.3 °C.** One saturated core is worth ~0.8 °C
  on this passively cooled board. Small, but it tracks, and it is read from
  `/sys/class/thermal` with no API call.
- **Frequency stayed flat at 1400 MHz.** On this device that is a
  _configuration_, not an observation: the owner has pinned the clock to maximum,
  which `/system/routerboard/settings` reports as
  `Warning: cpu not running at default frequency`. On a device that scales, the
  `freq_khz` field is where you would see a busy tick that was earned slowly.
  The agent reads the frequency every tick and stores `freq_khz` only when it
  changes, plus a heartbeat once every 60 s, so on a pinned clock you get one row
  a minute, and on a scaling clock you get every step that lasts at least one
  tick.

## Sampler check

Before you conclude anything from a CPU number, confirm
`mikroscope_slipped_total` is 0. A slipped tick is one whose read finished
after the next tick was due, and the sampler's own accounting is then the first
thing you should distrust.

## Kernel-bound load

The opposite shape: the cores are not busy, but the kernel is. It reached the
reference RB5009 on its own, on RouterOS 7.24.4, at 2026-09-23 12:08:50 UTC,
when a Home Assistant MikroTik integration started a wake-up storm:

- Timer interrupts went from about 2 500 to about 35 000 a second, in bursts of
  20–90 s on one core at a time, while user time and traffic stayed flat.
- It barely showed in RouterOS's own profile, and the busy columns above would
  not have caught it. The context-switch rate did: on that router it moved with
  the timer interrupts (r = 1.0).
- Disabling the integration on 2026-09-24 brought the timer back to about 2 500
  a second within 30 s.

It is one event on one router, read from the InfluxDB reference store, and it
has no case study of its own yet. The rule that watches for it is
`mikroscope-wakeup-storm` in [Alert rules](https://docs.jmrp.io/mikroscope/dashboards/alerts/),
which compares the last ten minutes' context-switch rate with the router's own
previous 24 hours.

## Signature

**Provoked on purpose** · 2026-09-12

- A device total near 100 % divided by the core count — here ~29 % on four
  cores — with one per-core column at 99.7–99.8 %.
- Before it settles, the load visibly hopping between cores for tens of seconds.
- A temperature rise of under a degree that tracks the load.

> **Not measured, so not claimed**
>
> A multi-threaded load, a load long enough to reach thermal equilibrium, and any change of clock
> frequency: the reference device's clock is pinned, so what a scaling governor does under this loop
> was not observed.

## See also

- [Resolution limits](https://docs.jmrp.io/mikroscope/limits/): why a 100 ms sample resolves one core
  in 10 % steps, and the PMU counters that read beneath it.
- [Record, mark and plot](https://docs.jmrp.io/mikroscope/record/): record a window like this one, with markers naming
  what else the router was doing.
- [Source cadences](https://docs.jmrp.io/mikroscope/limits/source-floors/): why temperature is read at the zone's
  declared 1 Hz and frequency is stored only when it changes.